← Ohio

Tap water quality report

Huber Heights Public Water

EPA monitoring tested this supplier for 84 contaminants and detected 26. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

84
contaminants tested
26
detected
43,439
people served
19
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Montgomery

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

19
health-based violations
32
violations on file
1
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 1993-07-01 → 1993-07-31
MCL Health-based Resolved 1993-07-01 → 1993-07-31
MCL Health-based Resolved 1993-07-01 → 1993-07-31
MCL Health-based Resolved 1993-07-01 → 1993-07-31
MCL Health-based Resolved 1992-08-01 → 1992-08-31
MCL Health-based Resolved 1992-08-01 → 1992-08-31
MCL Health-based Resolved 1992-08-01 → 1992-08-31
MCL Health-based Resolved 1992-08-01 → 1992-08-31
MCL Health-based Resolved 1992-08-01 → 1992-08-31
MCL Health-based Resolved 1992-08-01 → 1992-08-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
234 µg/L 18%
of the EPA limit 1300 µg/L
worst single sample: 368 µg/L
120/120 SYR4 2014–2019
Lead
18.9 µg/L 126%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 49.5 µg/L
76/120 SYR4 2014–2019
Bromodichloromethane
11.765 µg/L
No EPA limit set
worst single sample: 13.17 µg/L
75/76 SYR4 2012–2019
Chloroform
13.571 µg/L
No EPA limit set
worst single sample: 21.22 µg/L
75/76 SYR4 2012–2019
Dibromochloromethane
7.279 µg/L
No EPA limit set
worst single sample: 8.34 µg/L
75/76 SYR4 2012–2019
Bromoform
1.216 µg/L
No EPA limit set
worst single sample: 1.57 µg/L
57/76 SYR4 2012–2019
TTHM
35.5015 µg/L 44%
of the EPA limit 80 µg/L
worst single sample: 43.69 µg/L
40/40 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
26.213 µg/L 44%
of the EPA limit 60 µg/L
worst single sample: 41.9 µg/L
39/40 SYR4 2012–2019
Dibromoacetic Acid
3.1907 µg/L
No EPA limit set
worst single sample: 3.368 µg/L
35/40 SYR4 2012–2019
Dichloroacetic Acid
10.255 µg/L
No EPA limit set
worst single sample: 17.64 µg/L
35/40 SYR4 2012–2019
cis-1,2-Dichloroethylene
20.52 µg/L 29%
of the EPA limit 70 µg/L
worst single sample: 109 µg/L
34/154 SYR4 2012–2019
Trichloroacetic Acid
3.6156 µg/L
No EPA limit set
worst single sample: 4.906 µg/L
33/40 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
23/23 LCR 2025
Nitrate
334 µg/L 3.3%
of the EPA limit 10000 µg/L
10/32 SYR4 2012–2019
Barium
164 µg/L 8.2%
of the EPA limit 2000 µg/L
worst single sample: 166 µg/L
6/6 SYR4 2012–2018
Fluoride
1017.5 µg/L 25%
of the EPA limit 4000 µg/L
worst single sample: 1040 µg/L
6/6 SYR4 2012–2018
Monochloroacetic Acid
14.9 µg/L
No EPA limit set
worst single sample: 16.1 µg/L
6/40 SYR4 2012–2019
Cadmium
0.5630 µg/L 11%
of the EPA limit 5 µg/L
worst single sample: 0.5700 µg/L
2/6 SYR4 2012–2018
Combined Radium (-226 And -228)
0.9600 pCi/L 19%
of the EPA limit 5 pCi/L
1/2 SYR4 2015
Ethylbenzene
2.12 µg/L 0.3%
of the EPA limit 700 µg/L
1/155 SYR4 2012–2019
Nitrate-Nitrite
100 µg/L 1%
of the EPA limit 10000 µg/L
1/2 SYR4 2012
Thallium, Total
0.9200 µg/L 46%
of the EPA limit 2 µg/L
1/6 SYR4 2012–2018
Toluene
0.7600 µg/L 0.1%
of the EPA limit 1000 µg/L
1/155 SYR4 2012–2019
Vinyl Chloride
0.8000 µg/L 40%
of the EPA limit 2 µg/L
1/155 SYR4 2012–2019
Xylenes, Total
14.3 µg/L 0.1%
of the EPA limit 10000 µg/L
1/155 SYR4 2012–2019
trans-1,2-Dichloroethylene
1.68 µg/L 1.7%
of the EPA limit 100 µg/L
1/155 SYR4 2012–2019
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBenzeneBeryllium, TotalChlorobenzeneCyanideCarbon TetrachlorideChromiumDichloromethaneHfpo-DaLassoMercuryMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitritePfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaSeleniumSimazineStyreneTetrachloroethyleneTrichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzene

Utility contact

Contact
BUNNELL, GARY
Phone
937-233-3292
Email
[email protected]

Frequently asked questions about Huber Heights Public Water

Is Huber Heights Public Water tap water safe to drink?

EPA monitoring detected 26 contaminants in Huber Heights Public Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Huber Heights Public Water's water?

EPA monitoring detected Copper, Lead, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Huber Heights Public Water serve?

Huber Heights Public Water reports serving 43,439 people in Ohio, per its EPA record.

Has Huber Heights Public Water had any water quality violations?

The EPA has 32 violations on file for Huber Heights Public Water, of which 19 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.