← Ohio

Tap water quality report

Rockford Village

EPA monitoring tested this supplier for 56 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

56
contaminants tested
18
detected
1,120
people served
15
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Mercer

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

15
health-based violations
157
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2016-07-01 → 2016-12-31
TT Health-based Resolved 2016-07-01 → 2016-12-31
TT Health-based Resolved 2016-07-01 → 2016-12-31
TT Health-based Resolved 2016-07-01 → 2016-12-31
MCL Health-based Resolved 2014-07-01 → 2014-07-31
MCL Health-based Resolved 2014-07-01 → 2014-07-31
MCL Health-based Resolved 2014-07-01 → 2014-07-31
MCL Health-based Resolved 2014-07-01 → 2014-07-31
MCL Health-based Resolved 2006-02-01 → 2006-02-28
MCL Health-based Resolved 2006-02-01 → 2006-02-28

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
145.4 µg/L 11%
of the EPA limit 1300 µg/L
worst single sample: 451 µg/L
120/120 SYR4 2012–2019
Lead
0.0040 mg/L 27%
of the EPA limit 0.0150 mg/L
34/34 LCR 2025
Lead
18.1 µg/L 121%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 23.3 µg/L
26/120 SYR4 2012–2019
Nitrate
783 µg/L 7.8%
of the EPA limit 10000 µg/L
12/18 SYR4 2012–2019
Bromoform
14.628 µg/L
No EPA limit set
worst single sample: 19.6 µg/L
9/20 SYR4 2012–2019
Dibromochloromethane
12.392 µg/L
No EPA limit set
worst single sample: 13.94 µg/L
9/20 SYR4 2012–2019
TTHM
34.5245 µg/L 43%
of the EPA limit 80 µg/L
worst single sample: 38.98 µg/L
8/17 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
6.43865 µg/L 11%
of the EPA limit 60 µg/L
worst single sample: 7.65 µg/L
8/17 SYR4 2012–2019
Bromodichloromethane
5.993 µg/L
No EPA limit set
worst single sample: 6.23 µg/L
7/20 SYR4 2012–2019
Dibromoacetic Acid
4.7573 µg/L
No EPA limit set
worst single sample: 5.156 µg/L
7/17 SYR4 2012–2019
Chloroform
3.26 µg/L
No EPA limit set
worst single sample: 3.38 µg/L
5/20 SYR4 2012–2019
Arsenic
5.314 µg/L 53%
of the EPA limit 10 µg/L
worst single sample: 5.52 µg/L
3/35 SYR4 2012–2019
Fluoride
1415 µg/L 35%
of the EPA limit 4000 µg/L
worst single sample: 1430 µg/L
3/3 SYR4 2012–2018
Monochloroacetic Acid
2.09925 µg/L
No EPA limit set
worst single sample: 2.1 µg/L
2/17 SYR4 2012–2019
Barium
6.59 µg/L 0.3%
of the EPA limit 2000 µg/L
1/3 SYR4 2012–2018
Gross Alpha, Excl. Radon And U
26.4 pCi/L 176%
of the EPA limit, at the 95th percentile of samples — 15 pCi/L
1/1 SYR4 2015
Nitrate-Nitrite
783 µg/L 7.8%
of the EPA limit 10000 µg/L
1/2 SYR4 2012–2017
Trichloroacetic Acid
2.494 µg/L
No EPA limit set
1/17 SYR4 2012–2019
38 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalAsbestosAtrazineBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDichloroacetic AcidEthylbenzeneLassoMercuryMonobromoacetic AcidNitriteSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
TEMPLE, AARON
Phone
419-363-3032
Email
[email protected]

Frequently asked questions about Rockford Village

Is Rockford Village tap water safe to drink?

EPA monitoring detected 18 contaminants in Rockford Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Rockford Village's water?

EPA monitoring detected Copper, Lead, Lead, Nitrate, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Rockford Village serve?

Rockford Village reports serving 1,120 people in Ohio, per its EPA record.

Has Rockford Village had any water quality violations?

The EPA has 157 violations on file for Rockford Village, of which 15 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.