Tap water quality report

Syracuse Village

EPA monitoring tested this supplier for 53 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

53
contaminants tested
12
detected
826
people served
8
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Meigs

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
26
violations on file
7
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MCL Health-based Resolved 2004-03-01 → 2004-03-31
MCL Health-based Resolved 2004-03-01 → 2004-03-31
MCL Health-based Resolved 2004-03-01 → 2004-03-31
Other Monitoring Unaddressed 2026-01-06
RPT Monitoring Unaddressed 2025-07-02

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
241.2 µg/L 19%
of the EPA limit 1300 µg/L
worst single sample: 430 µg/L
33/40 SYR4 2012–2019
Lead
0.0042 mg/L 28%
of the EPA limit 0.0150 mg/L
21/21 LCR 2025
Nitrate
2250 µg/L 23%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Bromoform
9.718 µg/L
No EPA limit set
worst single sample: 14.8 µg/L
15/16 SYR4 2012–2019
Dibromochloromethane
4.742 µg/L
No EPA limit set
worst single sample: 4.84 µg/L
15/16 SYR4 2012–2019
TTHM
15.87 µg/L 20%
of the EPA limit 80 µg/L
worst single sample: 19.9 µg/L
14/15 SYR4 2012–2019
Bromodichloromethane
1.655 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
10/16 SYR4 2012–2019
Nitrate-Nitrite
2239.5 µg/L 22%
of the EPA limit 10000 µg/L
worst single sample: 2250 µg/L
8/8 SYR4 2012–2019
Dibromoacetic Acid
2.34 µg/L
No EPA limit set
worst single sample: 2.4 µg/L
7/15 SYR4 2012–2019
Lead
9.3 µg/L 62%
of the EPA limit 15 µg/L
worst single sample: 11 µg/L
6/40 SYR4 2012–2019
Barium
92.39 µg/L 4.6%
of the EPA limit 2000 µg/L
worst single sample: 94 µg/L
3/3 SYR4 2012–2018
Fluoride
127 µg/L 3.2%
of the EPA limit 4000 µg/L
1/3 SYR4 2012–2018
41 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalArsenicAsbestosAtrazineBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChloroformChromiumDichloromethaneDichloroacetic AcidEthylbenzeneLassoMercuryMonobromoacetic AcidMonochloroacetic AcidNitriteSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Trichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CUNNINGHAM, ERIC D.
Phone
740-992-7777
Email
[email protected]

Frequently asked questions about Syracuse Village

Is Syracuse Village tap water safe to drink?

EPA monitoring detected 12 contaminants in Syracuse Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Syracuse Village's water?

EPA monitoring detected Copper, Lead, Nitrate, Bromoform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Syracuse Village serve?

Syracuse Village reports serving 826 people in Ohio, per its EPA record.

Has Syracuse Village had any water quality violations?

The EPA has 26 violations on file for Syracuse Village, of which 8 are health-based (a contaminant limit or required treatment was breached) and 7 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.