← Ohio

Tap water quality report

Sebring Village

EPA monitoring tested this supplier for 83 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

83
contaminants tested
23
detected
6,058
people served
262
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Mahoning

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

262
health-based violations
328
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2020-11-01
TT Health-based Resolved 2020-11-01
TT Health-based Resolved 2020-11-01
TT Health-based Resolved 2020-11-01
TT Health-based Resolved 2020-11-01 → 2020-11-30
TT Health-based Resolved 2020-11-01 → 2020-11-30
TT Health-based Resolved 2020-11-01 → 2020-11-30
TT Health-based Resolved 2020-11-01 → 2020-11-30
TT Health-based Resolved 2020-11-01 → 2020-11-30
TT Health-based Resolved 2020-11-01 → 2020-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
363.8 µg/L 28%
of the EPA limit 1300 µg/L
worst single sample: 1980 µg/L
412/421 SYR4 2012–2019
Lead
24.478 µg/L 163%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 58.46 µg/L
368/1603 SYR4 2012–2019
Nitrate
2709.5 µg/L 27%
of the EPA limit 10000 µg/L
worst single sample: 3600 µg/L
182/192 SYR4 2012–2019
Chloroform
109.5 µg/L
No EPA limit set
worst single sample: 168 µg/L
66/69 SYR4 2012–2019
Bromodichloromethane
23.48 µg/L
No EPA limit set
worst single sample: 31.2 µg/L
65/69 SYR4 2012–2019
Dibromochloromethane
7.71 µg/L
No EPA limit set
worst single sample: 13 µg/L
64/69 SYR4 2012–2019
TTHM
131 µg/L 164%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 213 µg/L
61/61 SYR4 2012–2019
Dichloroacetic Acid
37.5 µg/L
No EPA limit set
worst single sample: 101 µg/L
56/60 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
79.39 µg/L 132%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 120 µg/L
55/59 SYR4 2012–2019
Trichloroacetic Acid
50.905 µg/L
No EPA limit set
worst single sample: 150 µg/L
52/60 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
34/34 LCR 2025
Bromoform
1.61 µg/L
No EPA limit set
worst single sample: 1.86 µg/L
29/69 SYR4 2012–2019
Dibromoacetic Acid
2.937 µg/L
No EPA limit set
worst single sample: 3.07 µg/L
20/60 SYR4 2012–2019
Monochloroacetic Acid
4.29 µg/L
No EPA limit set
worst single sample: 4.31 µg/L
11/60 SYR4 2012–2019
Monobromoacetic Acid
10.16 µg/L
No EPA limit set
worst single sample: 10.2 µg/L
9/60 SYR4 2012–2019
Barium
97.9 µg/L 4.9%
of the EPA limit 2000 µg/L
worst single sample: 121 µg/L
8/8 SYR4 2012–2019
Fluoride
1156 µg/L 29%
of the EPA limit 4000 µg/L
worst single sample: 1180 µg/L
7/8 SYR4 2012–2019
Arsenic
1.29 µg/L 13%
of the EPA limit 10 µg/L
worst single sample: 1.31 µg/L
3/8 SYR4 2012–2019
Chromium
1.1375 µg/L 1.1%
of the EPA limit 100 µg/L
worst single sample: 1.14 µg/L
2/8 SYR4 2012–2019
Nitrate-Nitrite
1628 µg/L 16%
of the EPA limit 10000 µg/L
worst single sample: 1700 µg/L
2/2 SYR4 2017–2018
Atrazine
0.3000 µg/L 10%
of the EPA limit 3 µg/L
1/20 SYR4 2012–2019
Mercury
0.2000 µg/L 10%
of the EPA limit 2 µg/L
1/8 SYR4 2012–2019
Selenium
1.12 µg/L 2.2%
of the EPA limit 50 µg/L
1/8 SYR4 2012–2019
60 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideDichloromethaneEthylbenzeneHfpo-DaLassoNetfosaaNfdhaNmefosaaNitritePfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GABRELCIK, TIM
Phone
330-938-9340
Email
[email protected]

Frequently asked questions about Sebring Village

Is Sebring Village tap water safe to drink?

EPA monitoring detected 23 contaminants in Sebring Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sebring Village's water?

EPA monitoring detected Copper, Lead, Nitrate, Chloroform, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Sebring Village serve?

Sebring Village reports serving 6,058 people in Ohio, per its EPA record.

Has Sebring Village had any water quality violations?

The EPA has 328 violations on file for Sebring Village, of which 262 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.