← Ohio

Tap water quality report

Byesville

EPA monitoring tested this supplier for 83 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

83
contaminants tested
19
detected
5,104
people served
378
health-based violations
Water source
Ground water under surface influence
Ownership
Local government
Counties served
Guernsey

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

378
health-based violations
530
violations on file
3
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-12-01 → 2024-12-31
TT Health-based Resolved 2024-12-01 → 2024-12-31
TT Health-based Resolved 2024-12-01 → 2024-12-31
TT Health-based Resolved 2024-12-01 → 2024-12-31
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-02-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
1322.5 µg/L 102%
of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 1480 µg/L
76/80 SYR4 2012–2019
Bromodichloromethane
53.48 µg/L
No EPA limit set
worst single sample: 75.2 µg/L
63/63 SYR4 2012–2019
Dibromochloromethane
97.48 µg/L
No EPA limit set
worst single sample: 120 µg/L
63/63 SYR4 2012–2019
TTHM
221.2 µg/L 276%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 278 µg/L
63/63 SYR4 2012–2019
Chloroform
35.685 µg/L
No EPA limit set
worst single sample: 54.3 µg/L
62/63 SYR4 2012–2019
Bromoform
66.9 µg/L
No EPA limit set
worst single sample: 111 µg/L
61/63 SYR4 2012–2019
Dibromoacetic Acid
55.725 µg/L
No EPA limit set
worst single sample: 63.1 µg/L
56/59 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
75.55 µg/L 126%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 105 µg/L
55/59 SYR4 2012–2019
Dichloroacetic Acid
26.54 µg/L
No EPA limit set
worst single sample: 45.5 µg/L
50/59 SYR4 2012–2019
Fluoride
988 µg/L 25%
of the EPA limit 4000 µg/L
worst single sample: 1790 µg/L
49/49 SYR4 2012–2019
Monobromoacetic Acid
7.785 µg/L
No EPA limit set
worst single sample: 8.3 µg/L
30/59 SYR4 2012–2019
Trichloroacetic Acid
4.4955 µg/L
No EPA limit set
worst single sample: 9.16 µg/L
24/59 SYR4 2012–2019
Lead
0.00086 mg/L 5.7%
of the EPA limit 0.0150 mg/L
18/18 LCR 2026
Monochloroacetic Acid
17.825 µg/L
No EPA limit set
worst single sample: 18.5 µg/L
16/59 SYR4 2012–2019
Lead
14.44 µg/L 96%
of the EPA limit 15 µg/L
worst single sample: 18.4 µg/L
13/80 SYR4 2012–2019
Nitrate
810 µg/L 8.1%
of the EPA limit 10000 µg/L
6/192 SYR4 2012–2019
Barium
44.16 µg/L 2.2%
of the EPA limit 2000 µg/L
worst single sample: 44.2 µg/L
5/8 SYR4 2012–2019
Lithium
30.7 µg/L
No EPA limit set
4/4 UCMR-5 2023
Nitrate-Nitrite
100 µg/L 1%
of the EPA limit 10000 µg/L
1/88 SYR4 2012–2019
64 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneEthylbenzeneGross Beta Particle ActivityHfpo-DaLassoMercuryNetfosaaNfdhaNmefosaaNitritePfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DUDLEY, BRENNAN
Phone
740-685-0800
Email
[email protected]

Frequently asked questions about Byesville

Is Byesville tap water safe to drink?

EPA monitoring detected 19 contaminants in Byesville's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Byesville's water?

EPA monitoring detected Copper, Bromodichloromethane, Dibromochloromethane, TTHM, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Byesville serve?

Byesville reports serving 5,104 people in Ohio, per its EPA record.

Has Byesville had any water quality violations?

The EPA has 530 violations on file for Byesville, of which 378 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.