| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2024-12-01 → 2024-12-31 |
| TT | Health-based | Resolved | 2024-12-01 → 2024-12-31 |
| TT | Health-based | Resolved | 2024-12-01 → 2024-12-31 |
| TT | Health-based | Resolved | 2024-12-01 → 2024-12-31 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-02-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 1322.5 µg/L 102% of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 1480 µg/L | 76/80 | SYR4 | 2012–2019 |
| Bromodichloromethane | 53.48 µg/L No EPA limit set
worst single sample: 75.2 µg/L | 63/63 | SYR4 | 2012–2019 |
| Dibromochloromethane | 97.48 µg/L No EPA limit set
worst single sample: 120 µg/L | 63/63 | SYR4 | 2012–2019 |
| TTHM | 221.2 µg/L 276% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 278 µg/L | 63/63 | SYR4 | 2012–2019 |
| Chloroform | 35.685 µg/L No EPA limit set
worst single sample: 54.3 µg/L | 62/63 | SYR4 | 2012–2019 |
| Bromoform | 66.9 µg/L No EPA limit set
worst single sample: 111 µg/L | 61/63 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 55.725 µg/L No EPA limit set
worst single sample: 63.1 µg/L | 56/59 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 75.55 µg/L 126% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 105 µg/L | 55/59 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 26.54 µg/L No EPA limit set
worst single sample: 45.5 µg/L | 50/59 | SYR4 | 2012–2019 |
| Fluoride | 988 µg/L 25% of the EPA limit 4000 µg/L
worst single sample: 1790 µg/L | 49/49 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 7.785 µg/L No EPA limit set
worst single sample: 8.3 µg/L | 30/59 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 4.4955 µg/L No EPA limit set
worst single sample: 9.16 µg/L | 24/59 | SYR4 | 2012–2019 |
| Lead | 0.00086 mg/L 5.7% of the EPA limit 0.0150 mg/L | 18/18 | LCR | 2026 |
| Monochloroacetic Acid | 17.825 µg/L No EPA limit set
worst single sample: 18.5 µg/L | 16/59 | SYR4 | 2012–2019 |
| Lead | 14.44 µg/L 96% of the EPA limit 15 µg/L
worst single sample: 18.4 µg/L | 13/80 | SYR4 | 2012–2019 |
| Nitrate | 810 µg/L 8.1% of the EPA limit 10000 µg/L | 6/192 | SYR4 | 2012–2019 |
| Barium | 44.16 µg/L 2.2% of the EPA limit 2000 µg/L
worst single sample: 44.2 µg/L | 5/8 | SYR4 | 2012–2019 |
| Lithium | 30.7 µg/L No EPA limit set | 4/4 | UCMR-5 | 2023 |
| Nitrate-Nitrite | 100 µg/L 1% of the EPA limit 10000 µg/L | 1/88 | SYR4 | 2012–2019 |
64 contaminants tested, none detected
Utility contact
Frequently asked questions about Byesville
Is Byesville tap water safe to drink?
EPA monitoring detected 19 contaminants in Byesville's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Byesville's water?
EPA monitoring detected Copper, Bromodichloromethane, Dibromochloromethane, TTHM, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Byesville serve?
Byesville reports serving 5,104 people in Ohio, per its EPA record.
Has Byesville had any water quality violations?
The EPA has 530 violations on file for Byesville, of which 378 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.