Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| Other | Monitoring | Unaddressed | 2026-01-07 |
| Other | Monitoring | Resolved | 2020-01-28 |
| Other | Monitoring | Resolved | 2020-01-28 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 1186 µg/L 91% of the EPA limit 1300 µg/L
worst single sample: 2000 µg/L | 138/141 | SYR4 | 2012–2019 |
| Bromodichloromethane | 17.58 µg/L No EPA limit set
worst single sample: 18 µg/L | 15/15 | SYR4 | 2012–2019 |
| Bromoform | 1.626 µg/L No EPA limit set
worst single sample: 1.92 µg/L | 15/15 | SYR4 | 2012–2019 |
| Chloroform | 31.4 µg/L No EPA limit set
worst single sample: 37.7 µg/L | 15/15 | SYR4 | 2012–2019 |
| Dibromochloromethane | 10.63 µg/L No EPA limit set
worst single sample: 11.4 µg/L | 15/15 | SYR4 | 2012–2019 |
| Lead | 0.0030 mg/L 20% of the EPA limit 0.0150 mg/L | 15/15 | LCR | 2025 |
| TTHM | 61.49 µg/L 77% of the EPA limit 80 µg/L
worst single sample: 67.3 µg/L | 15/15 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 15.449 µg/L 26% of the EPA limit 60 µg/L
worst single sample: 18.9 µg/L | 15/15 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 2.29995 µg/L No EPA limit set
worst single sample: 2.571 µg/L | 14/15 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 8.5014 µg/L No EPA limit set
worst single sample: 9.249 µg/L | 13/15 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 5.1092 µg/L No EPA limit set
worst single sample: 5.714 µg/L | 13/15 | SYR4 | 2012–2019 |
| Lead | 48.4 µg/L 323% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 55.4 µg/L | 5/141 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 9.547 µg/L No EPA limit set
worst single sample: 9.849 µg/L | 3/15 | SYR4 | 2012–2019 |
31 contaminants tested, none detected
Frequently asked questions about Greene County Eastern Regional
Is Greene County Eastern Regional tap water safe to drink?
EPA monitoring detected 13 contaminants in Greene County Eastern Regional's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Greene County Eastern Regional's water?
EPA monitoring detected Copper, Bromodichloromethane, Bromoform, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does Greene County Eastern Regional serve?
Greene County Eastern Regional reports serving 4,800 people, per its EPA record.
Has Greene County Eastern Regional had any water quality violations?
The EPA has 3 violations on file for Greene County Eastern Regional, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.