← Ohio

Tap water quality report

Greenfield Twp Water District

EPA monitoring tested this supplier for 82 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

82
contaminants tested
17
detected
490
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Fairfield

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
40
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2009-07-01
Other Monitoring Resolved 2009-07-01
Other Monitoring Resolved 2009-07-01
MR Monitoring Resolved 1999-01-01 → 1999-06-30
MR Monitoring Resolved 1999-01-01 → 1999-06-30
MR Monitoring Resolved 1999-01-01 → 1999-06-30
MR Monitoring Resolved 1997-01-01 → 1997-06-30
MR Monitoring Resolved 1997-01-01 → 1997-06-30
MR Monitoring Resolved 1997-01-01 → 1997-06-30
MR Monitoring Resolved 1997-01-01 → 1997-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
424.1 µg/L 33%
of the EPA limit 1300 µg/L
worst single sample: 2450 µg/L
19/32 SYR4 2013–2019
Chloroform
8.08 µg/L
No EPA limit set
worst single sample: 9.2 µg/L
17/17 SYR4 2013–2019
Dibromochloromethane
4.6 µg/L
No EPA limit set
worst single sample: 5 µg/L
17/17 SYR4 2013–2019
TTHM
20.4 µg/L 26%
of the EPA limit 80 µg/L
worst single sample: 22.8 µg/L
17/17 SYR4 2013–2019
Bromodichloromethane
7.025 µg/L
No EPA limit set
worst single sample: 7.7 µg/L
16/16 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
16/16 LCR 2025
Bromoform
0.7670 µg/L
No EPA limit set
worst single sample: 0.8000 µg/L
12/17 SYR4 2013–2019
Dichloroacetic Acid
1.955 µg/L
No EPA limit set
worst single sample: 2 µg/L
10/16 SYR4 2013–2019
Lead
1.86 µg/L 12%
of the EPA limit 15 µg/L
worst single sample: 2 µg/L
5/32 SYR4 2013–2019
Trichloroacetic Acid
2.16 µg/L
No EPA limit set
worst single sample: 2.4 µg/L
5/16 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
6.625 µg/L 11%
of the EPA limit 60 µg/L
worst single sample: 6.7 µg/L
4/18 SYR4 2013–2019
Barium
41.925 µg/L 2.1%
of the EPA limit 2000 µg/L
worst single sample: 42 µg/L
2/2 SYR4 2014–2017
Dibromoacetic Acid
1.1 µg/L
No EPA limit set
2/18 SYR4 2013–2019
Fluoride
288 µg/L 7.2%
of the EPA limit 4000 µg/L
worst single sample: 290 µg/L
2/2 SYR4 2014–2017
Arsenic
5 µg/L 50%
of the EPA limit 10 µg/L
1/2 SYR4 2014–2017
Monobromoacetic Acid
1.1 µg/L
No EPA limit set
1/18 SYR4 2013–2019
Lithium
9.78 µg/L
No EPA limit set
1/2 UCMR-5 2024
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneEthylbenzeneHfpo-DaLassoMercuryMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitrateNitrate-NitriteNitritePfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ANDERS, JOSHUA
Phone
614-419-3611
Email
[email protected]

Frequently asked questions about Greenfield Twp Water District

Is Greenfield Twp Water District tap water safe to drink?

EPA monitoring detected 17 contaminants in Greenfield Twp Water District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Greenfield Twp Water District's water?

EPA monitoring detected Copper, Chloroform, Dibromochloromethane, TTHM, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Greenfield Twp Water District serve?

Greenfield Twp Water District reports serving 490 people in Ohio, per its EPA record.

Has Greenfield Twp Water District had any water quality violations?

The EPA has 40 violations on file for Greenfield Twp Water District, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.