← Ohio

Tap water quality report

Del-Co Water Company, Inc.

EPA monitoring tested this supplier for 82 contaminants and detected 29. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

82
contaminants tested
29
detected
150,000
people served
4
health-based violations
Water source
Surface water
Ownership
Private
Counties served
Delaware

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
106
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 1994-01-01 → 1994-01-31
TT Health-based Resolved 1994-01-01 → 1994-01-31
TT Health-based Resolved 1994-01-01 → 1994-01-31
TT Health-based Resolved 1994-01-01 → 1994-01-31
MR Monitoring Resolved 2014-01-01 → 2014-06-30
MR Monitoring Resolved 2014-01-01 → 2014-06-30
MR Monitoring Resolved 2014-01-01 → 2014-06-30
MR Monitoring Resolved 2014-01-01 → 2014-06-30
MR Monitoring Resolved 2012-01-01 → 2012-12-31
MR Monitoring Resolved 2012-01-01 → 2012-12-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0107 µg/L 4/10 2024
PFBS 0.0043 µg/L 4/10 2024
Pfhxa 0.0087 µg/L 4/10 2024
Pfpea 0.0063 µg/L 4/10 2024
PFOA 0.0042 µg/L 1/10 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1704.5 µg/L 17%
of the EPA limit 10000 µg/L
worst single sample: 2300 µg/L
392/450 SYR4 2012–2019
Bromodichloromethane
15.37 µg/L
No EPA limit set
worst single sample: 18 µg/L
267/267 SYR4 2012–2019
Chloroform
57.75 µg/L
No EPA limit set
worst single sample: 75.7 µg/L
267/267 SYR4 2012–2019
Dibromochloromethane
4.6 µg/L
No EPA limit set
worst single sample: 5.5 µg/L
262/267 SYR4 2012–2019
Dichloroacetic Acid
22.8 µg/L
No EPA limit set
worst single sample: 29.6 µg/L
256/256 SYR4 2012–2019
TTHM
74.225 µg/L 93%
of the EPA limit 80 µg/L
worst single sample: 95.7 µg/L
256/256 SYR4 2012–2019
Trichloroacetic Acid
24.925 µg/L
No EPA limit set
worst single sample: 27.1 µg/L
256/256 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
49.69 µg/L 83%
of the EPA limit 60 µg/L
worst single sample: 58 µg/L
255/256 SYR4 2012–2019
Nitrate-Nitrite
1702.5 µg/L 17%
of the EPA limit 10000 µg/L
worst single sample: 2300 µg/L
196/225 SYR4 2012–2019
Copper
210 µg/L 16%
of the EPA limit 1300 µg/L
worst single sample: 2000 µg/L
154/194 SYR4 2012–2019
Monochloroacetic Acid
4.25 µg/L
No EPA limit set
worst single sample: 32.5 µg/L
116/256 SYR4 2012–2019
Atrazine
0.6580 µg/L 22%
of the EPA limit 3 µg/L
worst single sample: 1.55 µg/L
55/57 SYR4 2012–2019
Dibromoacetic Acid
1.465 µg/L
No EPA limit set
worst single sample: 1.6 µg/L
48/256 SYR4 2012–2019
Simazine
0.1780 µg/L 4.5%
of the EPA limit 4 µg/L
worst single sample: 0.4100 µg/L
43/57 SYR4 2012–2019
Fluoride
1095 µg/L 27%
of the EPA limit 4000 µg/L
worst single sample: 1200 µg/L
31/31 SYR4 2012–2019
Barium
21.9 µg/L 1.1%
of the EPA limit 2000 µg/L
worst single sample: 34 µg/L
23/31 SYR4 2012–2019
Lead
23 µg/L 153%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 35 µg/L
17/149 SYR4 2012–2018
Lead
0.00082 mg/L 5.5%
of the EPA limit 0.0150 mg/L
11/11 LCR 2024
Bromoform
0.5000 µg/L
No EPA limit set
6/267 SYR4 2012–2019
Monobromoacetic Acid
1.925 µg/L
No EPA limit set
worst single sample: 2.1 µg/L
6/256 SYR4 2012–2019
Toluene
0.8885 µg/L 0.1%
of the EPA limit 1000 µg/L
worst single sample: 0.9000 µg/L
2/28 SYR4 2012–2019
Xylenes, Total
1.4625 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 1.5 µg/L
2/29 SYR4 2012–2019
Lithium
12.9 µg/L
No EPA limit set
2/10 UCMR-5 2024
Lasso
0.6000 µg/L 30%
of the EPA limit 2 µg/L
1/57 SYR4 2012–2019
53 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneEthylbenzeneHfpo-DaMercuryNetfosaaNfdhaNmefosaaNitritePfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOSPfpesPftaPftrdaPfunaSeleniumStyreneTetrachloroethyleneThallium, TotalTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MARZLUF, GLENN
Phone
740-201-0125
Email
[email protected]

Frequently asked questions about Del-Co Water Company, Inc.

Is Del-Co Water Company, Inc. tap water safe to drink?

EPA monitoring detected 29 contaminants in Del-Co Water Company, Inc.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Del-Co Water Company, Inc.'s water?

EPA monitoring detected Nitrate, Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Del-Co Water Company, Inc. serve?

Del-Co Water Company, Inc. reports serving 150,000 people in Ohio, per its EPA record.

Has Del-Co Water Company, Inc. had any water quality violations?

The EPA has 106 violations on file for Del-Co Water Company, Inc., of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.