Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 1997-03-01 → 1997-03-31 |
| TT | Health-based | Resolved | 1997-03-01 → 1997-03-31 |
| TT | Health-based | Resolved | 1997-03-01 → 1997-03-31 |
| TT | Health-based | Resolved | 1997-03-01 → 1997-03-31 |
PFAS detected
| Contaminant | Max | Detection rate | Period |
|---|---|---|---|
| PFOA | 0.0079 µg/L | 2/2 | 2024 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 521.6 µg/L 40% of the EPA limit 1300 µg/L
worst single sample: 772 µg/L | 52/60 | SYR4 | 2012–2019 |
| Lead | 0.0036 mg/L 24% of the EPA limit 0.0150 mg/L | 21/21 | LCR | 2025 |
| Bromodichloromethane | 20.89 µg/L No EPA limit set
worst single sample: 21.8 µg/L | 14/14 | SYR4 | 2013–2019 |
| Bromoform | 5.1125 µg/L No EPA limit set
worst single sample: 5.6 µg/L | 14/14 | SYR4 | 2013–2019 |
| Chloroform | 22.175 µg/L No EPA limit set
worst single sample: 23.8 µg/L | 14/14 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 5.04 µg/L No EPA limit set
worst single sample: 5.3 µg/L | 14/14 | SYR4 | 2013–2019 |
| Dibromochloromethane | 18.22 µg/L No EPA limit set
worst single sample: 19 µg/L | 14/14 | SYR4 | 2013–2019 |
| TTHM | 61.34 µg/L 77% of the EPA limit 80 µg/L
worst single sample: 65.5 µg/L | 14/14 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 6.6 µg/L No EPA limit set
worst single sample: 7.2 µg/L | 13/14 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 14.3 µg/L 24% of the EPA limit 60 µg/L
worst single sample: 15.3 µg/L | 11/14 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 4.41 µg/L No EPA limit set
worst single sample: 4.5 µg/L | 10/14 | SYR4 | 2013–2019 |
| Lead | 37.62 µg/L 251% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 44.9 µg/L | 9/60 | SYR4 | 2012–2019 |
31 contaminants tested, none detected
Utility contact
Frequently asked questions about Bethel Village
Is Bethel Village tap water safe to drink?
EPA monitoring detected 13 contaminants in Bethel Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Bethel Village's water?
EPA monitoring detected Copper, Lead, Bromodichloromethane, Bromoform, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Bethel Village serve?
Bethel Village reports serving 2,620 people in Ohio, per its EPA record.
Has Bethel Village had any water quality violations?
The EPA has 130 violations on file for Bethel Village, of which 14 are health-based (a contaminant limit or required treatment was breached) and 5 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.