Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2016-01-01 → 2016-03-31 |
| MCL | Health-based | Resolved | 2016-01-01 → 2016-03-31 |
| MCL | Health-based | Resolved | 2016-01-01 → 2016-03-31 |
| MCL | Health-based | Resolved | 2016-01-01 → 2016-03-31 |
| MCL | Health-based | Resolved | 2015-10-01 → 2015-12-31 |
| MCL | Health-based | Resolved | 2015-10-01 → 2015-12-31 |
| MCL | Health-based | Resolved | 2015-10-01 → 2015-12-31 |
| MCL | Health-based | Resolved | 2015-10-01 → 2015-12-31 |
| MCL | Health-based | Resolved | 2015-10-01 → 2015-12-31 |
| MCL | Health-based | Resolved | 2015-10-01 → 2015-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 206.55 µg/L 16% of the EPA limit 1300 µg/L
worst single sample: 313 µg/L | 40/40 | SYR4 | 2014–2019 |
| Arsenic | 23.96 µg/L 240% of the EPA limit, at the 95th percentile of samples — 10 µg/L
worst single sample: 30 µg/L | 25/34 | SYR4 | 2012–2019 |
| Lead | 0.0040 mg/L 27% of the EPA limit 0.0150 mg/L | 21/21 | LCR | 2025 |
| Lead | 5.77 µg/L 38% of the EPA limit 15 µg/L
worst single sample: 7.03 µg/L | 10/40 | SYR4 | 2014–2019 |
| Chloroform | 7.689 µg/L No EPA limit set
worst single sample: 8.37 µg/L | 7/11 | SYR4 | 2012–2019 |
| Bromodichloromethane | 3.81 µg/L No EPA limit set
worst single sample: 3.99 µg/L | 6/11 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 2.69975 µg/L No EPA limit set
worst single sample: 2.735 µg/L | 4/9 | SYR4 | 2012–2019 |
| TTHM | 13.257 µg/L 17% of the EPA limit 80 µg/L
worst single sample: 13.92 µg/L | 4/9 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 6.2919 µg/L 10% of the EPA limit 60 µg/L
worst single sample: 6.414 µg/L | 4/9 | SYR4 | 2012–2019 |
| Dibromochloromethane | 1.544 µg/L No EPA limit set
worst single sample: 1.56 µg/L | 3/11 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 3.6311 µg/L No EPA limit set
worst single sample: 3.679 µg/L | 3/9 | SYR4 | 2012–2019 |
| Barium | 314.1 µg/L 16% of the EPA limit 2000 µg/L
worst single sample: 320 µg/L | 2/2 | SYR4 | 2014–2017 |
| Fluoride | 1198.8 µg/L 30% of the EPA limit 4000 µg/L
worst single sample: 1210 µg/L | 2/2 | SYR4 | 2014–2017 |
| Nitrate | 70 µg/L 0.7% of the EPA limit 10000 µg/L | 2/16 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 1.93 pCi/L 39% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2012 |
| Dibromoacetic Acid | 1.395 µg/L No EPA limit set | 1/9 | SYR4 | 2012–2019 |
37 contaminants tested, none detected
Utility contact
Frequently asked questions about Greenlawn Condos
Is Greenlawn Condos tap water safe to drink?
EPA monitoring detected 16 contaminants in Greenlawn Condos's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Greenlawn Condos's water?
EPA monitoring detected Copper, Arsenic, Lead, Lead, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Greenlawn Condos serve?
Greenlawn Condos reports serving 203 people in Ohio, per its EPA record.
Has Greenlawn Condos had any water quality violations?
The EPA has 346 violations on file for Greenlawn Condos, of which 99 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.