← Ohio

Tap water quality report

Oxford City

EPA monitoring tested this supplier for 81 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

81
contaminants tested
17
detected
24,000
people served
9
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Butler

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

9
health-based violations
17
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 1997-09-01 → 1997-09-30
MCL Health-based Resolved 1997-09-01 → 1997-09-30
MCL Health-based Resolved 1997-09-01 → 1997-09-30
MCL Health-based Resolved 1997-09-01 → 1997-09-30
MCL Health-based Resolved 1997-09-01 → 1997-09-30
MCL Health-based Resolved 1997-09-01 → 1997-09-30
MCL Health-based Resolved 1997-09-01 → 1997-09-30
MCL Health-based Resolved 1997-09-01 → 1997-09-30
MCL Health-based Resolved 1997-09-01 → 1997-09-30
MR Monitoring Resolved 2005-04-01 → 2005-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0126 µg/L 2/2 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
223.5 µg/L 17%
of the EPA limit 1300 µg/L
worst single sample: 1160 µg/L
128/128 SYR4 2013–2019
Lead
13.3925 µg/L 89%
of the EPA limit 15 µg/L
worst single sample: 31 µg/L
64/128 SYR4 2013–2019
Bromodichloromethane
7.217 µg/L
No EPA limit set
worst single sample: 9.8 µg/L
39/39 SYR4 2012–2019
Bromoform
1.416 µg/L
No EPA limit set
worst single sample: 1.84 µg/L
39/39 SYR4 2012–2019
Chloroform
6.186 µg/L
No EPA limit set
worst single sample: 14.23 µg/L
39/39 SYR4 2012–2019
Dibromochloromethane
6.179 µg/L
No EPA limit set
worst single sample: 7.06 µg/L
39/39 SYR4 2012–2019
TTHM
20.462 µg/L 26%
of the EPA limit 80 µg/L
worst single sample: 32.48 µg/L
37/37 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
6.69175 µg/L 11%
of the EPA limit 60 µg/L
worst single sample: 9.432 µg/L
36/37 SYR4 2012–2019
Dibromoacetic Acid
2.2386 µg/L
No EPA limit set
worst single sample: 2.666 µg/L
35/37 SYR4 2012–2019
Lead
0.0024 mg/L 16%
of the EPA limit 0.0150 mg/L
22/22 LCR 2025
Dichloroacetic Acid
3.6032 µg/L
No EPA limit set
worst single sample: 4.405 µg/L
20/37 SYR4 2012–2019
Nitrate
2800 µg/L 28%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Trichloroacetic Acid
2.51795 µg/L
No EPA limit set
worst single sample: 2.554 µg/L
8/37 SYR4 2012–2019
Barium
101.625 µg/L 5.1%
of the EPA limit 2000 µg/L
worst single sample: 102 µg/L
2/2 SYR4 2014–2017
Fluoride
1084.5 µg/L 27%
of the EPA limit 4000 µg/L
worst single sample: 1090 µg/L
2/2 SYR4 2014–2017
Nitrate-Nitrite
2210 µg/L 22%
of the EPA limit 10000 µg/L
1/1 SYR4 2012
64 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneEthylbenzeneHfpo-DaLassoMercuryMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaPfbaPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
KEHR, TODD
Phone
513-523-1753
Email
[email protected]

Frequently asked questions about Oxford City

Is Oxford City tap water safe to drink?

EPA monitoring detected 17 contaminants in Oxford City's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Oxford City's water?

EPA monitoring detected Copper, Lead, Bromodichloromethane, Bromoform, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Oxford City serve?

Oxford City reports serving 24,000 people in Ohio, per its EPA record.

Has Oxford City had any water quality violations?

The EPA has 17 violations on file for Oxford City, of which 9 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.