← New York

Tap water quality report

Ulster Water District

EPA monitoring tested this supplier for 101 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

101
contaminants tested
16
detected
5,500
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Ulster

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
64
violations on file
0
still open
ViolationTypeStatusPeriod
MON Monitoring Resolved 2023-11-01 → 2023-11-30
MON Monitoring Resolved 2023-11-01 → 2023-11-30
MON Monitoring Resolved 2023-11-01 → 2023-11-30
MR Monitoring Resolved 2017-07-01 → 2017-09-30
MR Monitoring Resolved 2017-07-01 → 2017-09-30
MR Monitoring Resolved 2017-07-01 → 2017-09-30
MR Monitoring Resolved 2017-07-01 → 2017-09-30
MR Monitoring Resolved 2017-07-01 → 2017-09-30
MR Monitoring Resolved 2017-07-01 → 2017-09-30
MR Monitoring Resolved 2017-07-01 → 2017-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
53.36 µg/L
No EPA limit set
worst single sample: 132 µg/L
57/57 SYR4 2012–2019
TTHM
70.32 µg/L 88%
of the EPA limit 80 µg/L
worst single sample: 134 µg/L
57/57 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
49.92 µg/L 83%
of the EPA limit 60 µg/L
worst single sample: 58 µg/L
57/57 SYR4 2012–2019
Bromodichloromethane
16.475 µg/L
No EPA limit set
worst single sample: 21.6 µg/L
56/57 SYR4 2012–2019
Dichloroacetic Acid
21.85 µg/L
No EPA limit set
worst single sample: 31.2 µg/L
56/57 SYR4 2012–2019
Trichloroacetic Acid
23.77 µg/L
No EPA limit set
worst single sample: 45 µg/L
54/57 SYR4 2012–2019
Dibromochloromethane
5.11 µg/L
No EPA limit set
worst single sample: 6.01 µg/L
19/57 SYR4 2012–2019
Monochloroacetic Acid
3.05 µg/L
No EPA limit set
worst single sample: 3.5 µg/L
11/57 SYR4 2012–2019
Lead
0.0021 mg/L 14%
of the EPA limit 0.0150 mg/L
10/10 LCR 2024
Dibromoacetic Acid
3.08 µg/L
No EPA limit set
worst single sample: 4.1 µg/L
9/57 SYR4 2012–2019
Monobromoacetic Acid
18.7 µg/L
No EPA limit set
worst single sample: 19.8 µg/L
5/57 SYR4 2012–2019
Barium
72.85 µg/L 3.6%
of the EPA limit 2000 µg/L
worst single sample: 73 µg/L
3/3 SYR4 2012–2018
Nitrate
30 µg/L 0.3%
of the EPA limit 10000 µg/L
2/16 SYR4 2012–2019
Arsenic
0.6000 µg/L 6%
of the EPA limit 10 µg/L
1/3 SYR4 2012–2018
Chromium
8.2 µg/L 8.2%
of the EPA limit 100 µg/L
1/3 SYR4 2012–2018
Fluoride
120 µg/L 3%
of the EPA limit 4000 µg/L
1/3 SYR4 2012–2018
85 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ULSTER TOWN SUPERVISOR
Phone
845-382-2765

Frequently asked questions about Ulster Water District

Is Ulster Water District tap water safe to drink?

EPA monitoring detected 16 contaminants in Ulster Water District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Ulster Water District's water?

EPA monitoring detected Chloroform, TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Ulster Water District serve?

Ulster Water District reports serving 5,500 people in New York, per its EPA record.

Has Ulster Water District had any water quality violations?

The EPA has 64 violations on file for Ulster Water District, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.