Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Archived | 2023-01-01 → 2023-12-31 |
| MR | Monitoring | Archived | 2023-01-01 → 2023-12-31 |
| MR | Monitoring | Archived | 2023-01-01 → 2023-12-31 |
| MR | Monitoring | Archived | 2023-01-01 → 2023-12-31 |
| MR | Monitoring | Archived | 2023-01-01 → 2023-12-31 |
| MR | Monitoring | Archived | 2023-01-01 → 2023-12-31 |
| MR | Monitoring | Addressed | 2021-10-01 |
| MR | Monitoring | Addressed | 2021-10-01 |
| MR | Monitoring | Addressed | 2021-10-01 |
| Other | Monitoring | Resolved | 2008-07-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 3622.5 µg/L 36% of the EPA limit 10000 µg/L
worst single sample: 4230 µg/L | 30/34 | SYR4 | 2012–2019 |
| Lead | 0.0010 mg/L 6.7% of the EPA limit 0.0150 mg/L | 13/13 | LCR | 2023 |
| Nitrate-Nitrite | 3420 µg/L 34% of the EPA limit 10000 µg/L
worst single sample: 4230 µg/L | 13/13 | SYR4 | 2014–2019 |
| Dibromochloromethane | 0.8360 µg/L No EPA limit set
worst single sample: 0.8400 µg/L | 5/6 | SYR4 | 2013–2015 |
| TTHM | 6.712 µg/L 8.4% of the EPA limit 80 µg/L
worst single sample: 6.8 µg/L | 5/9 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 4.264 µg/L 7.1% of the EPA limit 60 µg/L
worst single sample: 4.53 µg/L | 5/9 | SYR4 | 2013–2019 |
| Barium | 111.4 µg/L 5.6% of the EPA limit 2000 µg/L
worst single sample: 115 µg/L | 4/4 | SYR4 | 2014–2017 |
| Bromodichloromethane | 0.7245 µg/L No EPA limit set
worst single sample: 0.7500 µg/L | 4/6 | SYR4 | 2013–2015 |
| Chloroform | 0.7815 µg/L No EPA limit set
worst single sample: 0.7900 µg/L | 2/3 | SYR4 | 2013–2015 |
| Combined Radium (-226 And -228) | 1.20835 pCi/L 24% of the EPA limit 5 pCi/L
worst single sample: 1.244 pCi/L | 2/2 | SYR4 | 2019 |
| Dichloroacetic Acid | 4.518 µg/L No EPA limit set
worst single sample: 4.53 µg/L | 2/5 | SYR4 | 2013–2015 |
| Bromoform | 0.5000 µg/L No EPA limit set | 1/5 | SYR4 | 2013–2015 |
| Monochloroacetic Acid | 1.2 µg/L No EPA limit set | 1/5 | SYR4 | 2013–2015 |
59 contaminants tested, none detected
Utility contact
Frequently asked questions about Candor Village Water Dept.
Is Candor Village Water Dept. tap water safe to drink?
EPA monitoring detected 13 contaminants in Candor Village Water Dept.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Candor Village Water Dept.'s water?
EPA monitoring detected Nitrate, Lead, Nitrate-Nitrite, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.
How many people does Candor Village Water Dept. serve?
Candor Village Water Dept. reports serving 800 people in New York, per its EPA record.
Has Candor Village Water Dept. had any water quality violations?
The EPA has 52 violations on file for Candor Village Water Dept., of which 0 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.