Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| RPT | Monitoring | Resolved | 2024-10-17 |
| RPT | Monitoring | Resolved | 2024-10-17 |
| RPT | Monitoring | Resolved | 2024-10-17 |
| MON | Monitoring | Resolved | 2019-06-01 → 2019-06-30 |
| MON | Monitoring | Resolved | 2019-06-01 → 2019-06-30 |
| Other | Monitoring | Resolved | 2009-06-01 → 2009-06-30 |
| Other | Monitoring | Resolved | 2009-06-01 → 2009-06-30 |
| Other | Monitoring | Resolved | 2009-06-01 → 2009-06-30 |
| Other | Monitoring | Resolved | 2009-03-01 → 2009-03-31 |
| Other | Monitoring | Resolved | 2009-03-01 → 2009-03-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 353 µg/L 3.5% of the EPA limit 10000 µg/L | 20/20 | SYR4 | 2012–2019 |
| Lead | 0.0053 mg/L 35% of the EPA limit 0.0150 mg/L | 5/5 | LCR | 2023 |
| Arsenic | 3.7 µg/L 37% of the EPA limit 10 µg/L | 4/4 | SYR4 | 2012–2018 |
| Barium | 311.65 µg/L 16% of the EPA limit 2000 µg/L
worst single sample: 313 µg/L | 4/4 | SYR4 | 2012–2018 |
| Combined Radium (-226 And -228) | 1.424 pCi/L 28% of the EPA limit 5 pCi/L
worst single sample: 1.48 pCi/L | 3/3 | SYR4 | 2018 |
| Combined Uranium | 7.242 µg/L 24% of the EPA limit 30 µg/L
worst single sample: 7.3 µg/L | 3/3 | SYR4 | 2018 |
| Bromodichloromethane | 2.355 µg/L No EPA limit set
worst single sample: 2.4 µg/L | 2/2 | SYR4 | 2014–2017 |
| Chloroform | 5.35 µg/L No EPA limit set
worst single sample: 5.5 µg/L | 2/2 | SYR4 | 2014–2017 |
| Dibromochloromethane | 1.285 µg/L No EPA limit set
worst single sample: 1.3 µg/L | 2/2 | SYR4 | 2014–2017 |
| Dichloroacetic Acid | 2.45 µg/L No EPA limit set
worst single sample: 2.5 µg/L | 2/2 | SYR4 | 2014–2017 |
| Gross Alpha, Excl. Radon And U | 2.816 pCi/L 19% of the EPA limit 15 pCi/L
worst single sample: 2.88 pCi/L | 2/3 | SYR4 | 2018 |
| TTHM | 8.99 µg/L 11% of the EPA limit 80 µg/L
worst single sample: 9.2 µg/L | 2/2 | SYR4 | 2014–2017 |
| Total Haloacetic Acids (HAA5) | 3.55 µg/L 5.9% of the EPA limit 60 µg/L
worst single sample: 3.6 µg/L | 2/2 | SYR4 | 2014–2017 |
| Trichloroacetic Acid | 1.0985 µg/L No EPA limit set
worst single sample: 1.1 µg/L | 2/2 | SYR4 | 2014–2017 |
59 contaminants tested, none detected
Utility contact
Frequently asked questions about Crystal Water Supply Company
Is Crystal Water Supply Company tap water safe to drink?
EPA monitoring detected 14 contaminants in Crystal Water Supply Company's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Crystal Water Supply Company's water?
EPA monitoring detected Nitrate, Lead, Arsenic, Barium, Combined Radium (-226 And -228), and others. The full list with the level and data source for each is above.
How many people does Crystal Water Supply Company serve?
Crystal Water Supply Company reports serving 146 people in Florida, per its EPA record.
Has Crystal Water Supply Company had any water quality violations?
The EPA has 24 violations on file for Crystal Water Supply Company, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.