Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2012-06-01 → 2012-06-30 |
| MCL | Health-based | Resolved | 2012-06-01 → 2012-06-30 |
| MCL | Health-based | Resolved | 2012-06-01 → 2012-06-30 |
| MCL | Health-based | Resolved | 2012-06-01 → 2012-06-30 |
| MCL | Health-based | Resolved | 2012-06-01 → 2012-06-30 |
| MCL | Health-based | Resolved | 2012-06-01 → 2012-06-30 |
| MCL | Health-based | Resolved | 2012-06-01 → 2012-06-30 |
| MON | Monitoring | Archived | 2025-11-01 → 2025-11-30 |
| MON | Monitoring | Archived | 2025-11-01 → 2025-11-30 |
| MON | Monitoring | Resolved | 2023-03-01 → 2023-03-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 707 µg/L 7.1% of the EPA limit 10000 µg/L | 16/16 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 11/11 | LCR | 2025 |
| Nitrate-Nitrite | 706.75 µg/L 7.1% of the EPA limit 10000 µg/L
worst single sample: 707 µg/L | 6/6 | SYR4 | 2014–2019 |
| Barium | 34.095 µg/L 1.7% of the EPA limit 2000 µg/L
worst single sample: 34.1 µg/L | 2/2 | SYR4 | 2018–2019 |
| Bromodichloromethane | 0.7950 µg/L No EPA limit set
worst single sample: 0.8000 µg/L | 2/3 | SYR4 | 2013–2019 |
| Bromoform | 1.1815 µg/L No EPA limit set
worst single sample: 1.2 µg/L | 2/3 | SYR4 | 2013–2019 |
| Dibromochloromethane | 1.395 µg/L No EPA limit set
worst single sample: 1.4 µg/L | 2/3 | SYR4 | 2013–2019 |
| TTHM | 3.19 µg/L 4% of the EPA limit 80 µg/L
worst single sample: 3.2 µg/L | 2/3 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 0.7000 µg/L No EPA limit set | 1/3 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 1.7 µg/L No EPA limit set | 1/3 | SYR4 | 2013–2019 |
| Monobromoacetic Acid | 1.8 µg/L No EPA limit set | 1/3 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 6.1 µg/L 10% of the EPA limit 60 µg/L | 1/3 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 1.9 µg/L No EPA limit set | 1/3 | SYR4 | 2013–2019 |
59 contaminants tested, none detected
Utility contact
Frequently asked questions about Butler Estates (Court)
Is Butler Estates (Court) tap water safe to drink?
EPA monitoring detected 13 contaminants in Butler Estates (Court)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Butler Estates (Court)'s water?
EPA monitoring detected Nitrate, Lead, Nitrate-Nitrite, Barium, Bromodichloromethane, and others. The full list with the level and data source for each is above.
How many people does Butler Estates (Court) serve?
Butler Estates (Court) reports serving 38 people in New York, per its EPA record.
Has Butler Estates (Court) had any water quality violations?
The EPA has 691 violations on file for Butler Estates (Court), of which 7 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.