Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2011-12-01 → 2011-12-31 |
| TT | Health-based | Resolved | 2011-12-01 → 2011-12-31 |
| TT | Health-based | Resolved | 2011-12-01 → 2011-12-31 |
| TT | Health-based | Resolved | 2011-12-01 → 2011-12-31 |
| TT | Health-based | Resolved | 2011-11-01 → 2011-11-30 |
| TT | Health-based | Resolved | 2011-11-01 → 2011-11-30 |
| TT | Health-based | Resolved | 2011-11-01 → 2011-11-30 |
| TT | Health-based | Resolved | 2011-11-01 → 2011-11-30 |
| TT | Health-based | Resolved | 2011-09-01 → 2011-09-30 |
| TT | Health-based | Resolved | 2011-09-01 → 2011-09-30 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 82.36 µg/L 103% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 110 µg/L | 149/151 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 50.34 µg/L 84% of the EPA limit 60 µg/L
worst single sample: 109.4 µg/L | 143/147 | SYR4 | 2012–2019 |
| Nitrate | 4310 µg/L 43% of the EPA limit 10000 µg/L
worst single sample: 5230 µg/L | 56/64 | SYR4 | 2012–2019 |
| Barium | 36.46 µg/L 1.8% of the EPA limit 2000 µg/L
worst single sample: 74 µg/L | 29/29 | SYR4 | 2012–2019 |
| Lead | 0.0010 mg/L 6.7% of the EPA limit 0.0150 mg/L | 22/22 | LCR | 2025 |
| Combined Uranium | 1.76848 µg/L 5.9% of the EPA limit 30 µg/L
worst single sample: 1.7731 µg/L | 5/15 | SYR4 | 2013–2019 |
| Fluoride | 886.8 µg/L 22% of the EPA limit 4000 µg/L
worst single sample: 978 µg/L | 4/30 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 2.74 pCi/L 18% of the EPA limit 15 pCi/L | 4/9 | SYR4 | 2013–2019 |
| Arsenic | 1.075 µg/L 11% of the EPA limit 10 µg/L
worst single sample: 1.1 µg/L | 2/29 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 1.8195 pCi/L 36% of the EPA limit 5 pCi/L
worst single sample: 1.86 pCi/L | 2/15 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 379.79 µg/L 3.8% of the EPA limit 10000 µg/L
worst single sample: 396 µg/L | 2/2 | SYR4 | 2017 |
| 2,4-D | 0.3500 µg/L 0.5% of the EPA limit 70 µg/L | 1/33 | SYR4 | 2013–2019 |
| Dalapon | 1.23 µg/L 0.6% of the EPA limit 200 µg/L | 1/33 | SYR4 | 2013–2019 |
80 contaminants tested, none detected
Utility contact
Frequently asked questions about New Windsor Consolidated Wd
Is New Windsor Consolidated Wd tap water safe to drink?
EPA monitoring detected 16 contaminants in New Windsor Consolidated Wd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in New Windsor Consolidated Wd's water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Nitrate, Barium, Lead, and others. The full list with the level and data source for each is above.
How many people does New Windsor Consolidated Wd serve?
New Windsor Consolidated Wd reports serving 25,667 people in New York, per its EPA record.
Has New Windsor Consolidated Wd had any water quality violations?
The EPA has 86 violations on file for New Windsor Consolidated Wd, of which 34 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.