← New York

Tap water quality report

Hopewell Cons Wd 1

EPA monitoring tested this supplier for 42 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

42
contaminants tested
10
detected
3,781
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Ontario

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
6
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2011-01-01
Other Monitoring Resolved 2011-01-01
Other Monitoring Resolved 2007-07-01
Other Monitoring Resolved 2007-07-01
Other Monitoring Resolved 1994-09-01 → 1994-09-30
Other Monitoring Resolved 1994-09-01 → 1994-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Dichloroacetic Acid
17.55 µg/L
No EPA limit set
worst single sample: 22 µg/L
50/50 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
42.55 µg/L 71%
of the EPA limit 60 µg/L
worst single sample: 47 µg/L
50/50 SYR4 2013–2019
Trichloroacetic Acid
28.55 µg/L
No EPA limit set
worst single sample: 31 µg/L
50/50 SYR4 2013–2019
Bromodichloromethane
18.6 µg/L
No EPA limit set
worst single sample: 20 µg/L
49/49 SYR4 2013–2019
Chloroform
62.2 µg/L
No EPA limit set
worst single sample: 69 µg/L
49/49 SYR4 2013–2019
Dibromochloromethane
4.36 µg/L
No EPA limit set
worst single sample: 4.8 µg/L
49/49 SYR4 2013–2019
TTHM
85.6 µg/L 107%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 88 µg/L
49/49 SYR4 2013–2019
Monochloroacetic Acid
2.385 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
14/50 SYR4 2013–2019
Lead
0.0013 mg/L 8.7%
of the EPA limit 0.0150 mg/L
9/9 LCR 2023
Monobromoacetic Acid
1 µg/L
No EPA limit set
2/50 SYR4 2013–2019
32 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaBromoformDibromoacetic AcidHfpo-DaNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
ECKAM, JOE
Phone
585-394-3960
Email
[email protected]

Frequently asked questions about Hopewell Cons Wd 1

Is Hopewell Cons Wd 1 tap water safe to drink?

EPA monitoring detected 10 contaminants in Hopewell Cons Wd 1's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Hopewell Cons Wd 1's water?

EPA monitoring detected Dichloroacetic Acid, Total Haloacetic Acids (HAA5), Trichloroacetic Acid, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Hopewell Cons Wd 1 serve?

Hopewell Cons Wd 1 reports serving 3,781 people in New York, per its EPA record.

Has Hopewell Cons Wd 1 had any water quality violations?

The EPA has 6 violations on file for Hopewell Cons Wd 1, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.