← New York

Tap water quality report

Sea Breeze Wd

EPA monitoring tested this supplier for 44 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
13
detected
7,800
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Monroe

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
18
violations on file
12
still open
ViolationTypeStatusPeriod
MR Monitoring Archived 2026-01-01 → 2026-03-31
MR Monitoring Archived 2026-01-01 → 2026-03-31
MR Monitoring Unaddressed 2024-07-01
MR Monitoring Unaddressed 2024-07-01
MR Monitoring Unaddressed 2024-07-01
MR Monitoring Unaddressed 2024-07-01
MR Monitoring Unaddressed 2024-01-01
MR Monitoring Unaddressed 2024-01-01
MR Monitoring Archived 2023-07-01 → 2023-09-30
MR Monitoring Archived 2023-07-01 → 2023-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
56.4 µg/L 71%
of the EPA limit 80 µg/L
worst single sample: 68 µg/L
57/57 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
22 µg/L 37%
of the EPA limit 60 µg/L
worst single sample: 39 µg/L
57/57 SYR4 2012–2019
Bromodichloromethane
17 µg/L
No EPA limit set
worst single sample: 19 µg/L
41/41 SYR4 2014–2019
Chloroform
32 µg/L
No EPA limit set
worst single sample: 39 µg/L
41/41 SYR4 2014–2019
Dibromochloromethane
7.2 µg/L
No EPA limit set
worst single sample: 9.2 µg/L
41/41 SYR4 2014–2019
Dichloroacetic Acid
12 µg/L
No EPA limit set
worst single sample: 19 µg/L
41/41 SYR4 2014–2019
Trichloroacetic Acid
11 µg/L
No EPA limit set
worst single sample: 19 µg/L
41/41 SYR4 2014–2019
Bromoform
3.13 µg/L
No EPA limit set
worst single sample: 3.2 µg/L
15/41 SYR4 2014–2019
Lead
0.0030 mg/L 20%
of the EPA limit 0.0150 mg/L
12/12 LCR 2025
Monochloroacetic Acid
1.9 µg/L
No EPA limit set
10/41 SYR4 2014–2019
Dibromoacetic Acid
1.1 µg/L
No EPA limit set
3/41 SYR4 2014–2019
Copper
195.9 µg/L 15%
of the EPA limit 1300 µg/L
worst single sample: 200 µg/L
2/2 SYR4 2012–2015
Lead
11.645 µg/L 78%
of the EPA limit 15 µg/L
worst single sample: 12 µg/L
2/2 SYR4 2012–2015
31 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaHfpo-DaMonobromoacetic AcidNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
PUTNAM, LINDSAY G.
Phone
585-467-6341
Email
[email protected]

Frequently asked questions about Sea Breeze Wd

Is Sea Breeze Wd tap water safe to drink?

EPA monitoring detected 13 contaminants in Sea Breeze Wd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sea Breeze Wd's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Sea Breeze Wd serve?

Sea Breeze Wd reports serving 7,800 people in New York, per its EPA record.

Has Sea Breeze Wd had any water quality violations?

The EPA has 18 violations on file for Sea Breeze Wd, of which 0 are health-based (a contaminant limit or required treatment was breached) and 12 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.