Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| Other | Monitoring | Unaddressed | 2025-09-02 |
| Other | Monitoring | Unaddressed | 2025-07-01 |
| MR | Monitoring | Archived | 2025-04-01 → 2025-06-30 |
| MR | Monitoring | Archived | 2025-04-01 → 2025-06-30 |
| MON | Monitoring | Resolved | 2024-12-01 → 2024-12-31 |
| MON | Monitoring | Resolved | 2024-12-01 → 2024-12-31 |
| MON | Monitoring | Resolved | 2024-12-01 → 2024-12-31 |
| MR | Monitoring | Archived | 2024-10-01 → 2024-12-31 |
| MR | Monitoring | Archived | 2024-10-01 → 2024-12-31 |
| MR | Monitoring | Archived | 2024-10-01 → 2024-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 370 µg/L 3.7% of the EPA limit 10000 µg/L | 12/12 | SYR4 | 2014–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 9/9 | LCR | 2025 |
| TTHM | 20.69 µg/L 26% of the EPA limit 80 µg/L
worst single sample: 20.7 µg/L | 3/3 | SYR4 | 2013–2019 |
| Barium | 110.9 µg/L 5.5% of the EPA limit 2000 µg/L
worst single sample: 114 µg/L | 2/2 | SYR4 | 2014–2017 |
| Total Haloacetic Acids (HAA5) | 4.66 µg/L 7.8% of the EPA limit 60 µg/L
worst single sample: 4.8 µg/L | 2/2 | SYR4 | 2016–2019 |
| Bromodichloromethane | 1.8 µg/L No EPA limit set | 1/1 | SYR4 | 2013 |
| Bromoform | 11 µg/L No EPA limit set | 1/1 | SYR4 | 2013 |
| Chloroform | 0.8700 µg/L No EPA limit set | 1/1 | SYR4 | 2013 |
| Combined Radium (-226 And -228) | 3 pCi/L 60% of the EPA limit 5 pCi/L | 1/2 | SYR4 | 2014–2017 |
| Dibromochloromethane | 5 µg/L No EPA limit set | 1/1 | SYR4 | 2013 |
| Gross Alpha, Excl. Radon And U | 3 pCi/L 20% of the EPA limit 15 pCi/L | 1/1 | SYR4 | 2014 |
| Nitrate-Nitrite | 240 µg/L 2.4% of the EPA limit 10000 µg/L | 1/1 | SYR4 | 2013 |
| Toluene | 2.3 µg/L 0.2% of the EPA limit 1000 µg/L | 1/10 | SYR4 | 2014–2018 |
55 contaminants tested, none detected
Utility contact
Frequently asked questions about Crystal Pond Water Works
Is Crystal Pond Water Works tap water safe to drink?
EPA monitoring detected 13 contaminants in Crystal Pond Water Works's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Crystal Pond Water Works's water?
EPA monitoring detected Nitrate, Lead, TTHM, Barium, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Crystal Pond Water Works serve?
Crystal Pond Water Works reports serving 250 people in New York, per its EPA record.
Has Crystal Pond Water Works had any water quality violations?
The EPA has 253 violations on file for Crystal Pond Water Works, of which 0 are health-based (a contaminant limit or required treatment was breached) and 6 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.