Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2007-01-01 → 2007-03-31 |
| MCL | Health-based | Resolved | 2007-01-01 → 2007-03-31 |
| MCL | Health-based | Resolved | 2007-01-01 → 2007-03-31 |
| MCL | Health-based | Resolved | 2007-01-01 → 2007-03-31 |
| MCL | Health-based | Resolved | 2006-10-01 → 2006-12-31 |
| MCL | Health-based | Resolved | 2006-10-01 → 2006-12-31 |
| MCL | Health-based | Resolved | 2006-10-01 → 2006-12-31 |
| MCL | Health-based | Resolved | 2006-10-01 → 2006-12-31 |
| MCL | Health-based | Resolved | 2006-10-01 → 2006-12-31 |
| MCL | Health-based | Resolved | 2006-10-01 → 2006-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 15 µg/L No EPA limit set
worst single sample: 23 µg/L | 31/31 | SYR4 | 2012–2019 |
| Chloroform | 76.5 µg/L No EPA limit set
worst single sample: 93 µg/L | 31/31 | SYR4 | 2012–2019 |
| Dibromochloromethane | 17 µg/L No EPA limit set
worst single sample: 25 µg/L | 31/31 | SYR4 | 2012–2019 |
| TTHM | 91.5 µg/L 114% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 110 µg/L | 31/31 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 72 µg/L 120% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 82.94 µg/L | 31/31 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 28.5 µg/L No EPA limit set
worst single sample: 31 µg/L | 31/31 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 40.95 µg/L No EPA limit set
worst single sample: 47 µg/L | 30/31 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 7.48 µg/L No EPA limit set
worst single sample: 7.5 µg/L | 22/31 | SYR4 | 2012–2019 |
| Bromoform | 10.25 µg/L No EPA limit set
worst single sample: 11 µg/L | 16/31 | SYR4 | 2012–2019 |
| Lead | 0.0020 mg/L 13% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2024 |
| Monochloroacetic Acid | 3.91 µg/L No EPA limit set
worst single sample: 4.3 µg/L | 14/31 | SYR4 | 2012–2019 |
| Nitrate | 850 µg/L 8.5% of the EPA limit 10000 µg/L | 12/18 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 4.65 µg/L No EPA limit set
worst single sample: 7.5 µg/L | 11/31 | SYR4 | 2012–2019 |
| Barium | 714 µg/L 36% of the EPA limit 2000 µg/L
worst single sample: 771 µg/L | 4/4 | SYR4 | 2014–2019 |
| Fluoride | 786.5 µg/L 20% of the EPA limit 4000 µg/L
worst single sample: 890 µg/L | 4/4 | SYR4 | 2014–2019 |
| Arsenic | 3.56 µg/L 36% of the EPA limit 10 µg/L
worst single sample: 3.8 µg/L | 3/4 | SYR4 | 2014–2019 |
| Chromium | 2.0985 µg/L 2.1% of the EPA limit 100 µg/L
worst single sample: 2.2 µg/L | 2/4 | SYR4 | 2014–2019 |
| 2,4-D | 0.1500 µg/L 0.2% of the EPA limit 70 µg/L | 1/18 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 0.6600 pCi/L 13% of the EPA limit 5 pCi/L | 1/3 | SYR4 | 2015–2018 |
| Combined Uranium | 1.06 µg/L 3.5% of the EPA limit 30 µg/L | 1/2 | SYR4 | 2015–2018 |
| Di(2-ethylhexyl) Phthalate | 0.9000 µg/L 15% of the EPA limit 6 µg/L | 1/16 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 1.41 pCi/L 9.4% of the EPA limit 15 pCi/L | 1/2 | SYR4 | 2015–2018 |
| Picloram | 45 µg/L 9% of the EPA limit 500 µg/L | 1/18 | SYR4 | 2012–2019 |
| Thallium, Total | 0.0370 µg/L 1.9% of the EPA limit 2 µg/L | 1/4 | SYR4 | 2014–2019 |
78 contaminants tested, none detected
Utility contact
Frequently asked questions about Collins/Gowanda Correctional Facility
Is Collins/Gowanda Correctional Facility tap water safe to drink?
EPA monitoring detected 24 contaminants in Collins/Gowanda Correctional Facility's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Collins/Gowanda Correctional Facility's water?
EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Collins/Gowanda Correctional Facility serve?
Collins/Gowanda Correctional Facility reports serving 1,512 people in New York, per its EPA record.
Has Collins/Gowanda Correctional Facility had any water quality violations?
The EPA has 70 violations on file for Collins/Gowanda Correctional Facility, of which 65 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.