Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 2007-06-01 |
| MR | Monitoring | Resolved | 2007-06-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 25.575 µg/L No EPA limit set
worst single sample: 31.8 µg/L | 86/86 | SYR4 | 2012–2019 |
| Chloroform | 74.625 µg/L No EPA limit set
worst single sample: 90.6 µg/L | 86/86 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 31 µg/L No EPA limit set
worst single sample: 37 µg/L | 86/86 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 21.85 µg/L No EPA limit set
worst single sample: 25 µg/L | 84/85 | SYR4 | 2012–2019 |
| Dibromochloromethane | 19.6 µg/L No EPA limit set
worst single sample: 36.1 µg/L | 81/86 | SYR4 | 2012–2019 |
| TTHM | 101.12 µg/L 126% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 120.6 µg/L | 67/67 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 59 µg/L 98% of the EPA limit 60 µg/L
worst single sample: 103 µg/L | 67/67 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 5.5 µg/L No EPA limit set
worst single sample: 8.5 µg/L | 33/86 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 21/21 | LCR | 2026 |
| Monobromoacetic Acid | 23.925 µg/L No EPA limit set
worst single sample: 24 µg/L | 16/86 | SYR4 | 2012–2019 |
| Bromoform | 8.274 µg/L No EPA limit set
worst single sample: 11.2 µg/L | 12/86 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 23.4 µg/L No EPA limit set
worst single sample: 24 µg/L | 5/86 | SYR4 | 2012–2019 |
Utility contact
Frequently asked questions about Central Dutchess Water Line
Is Central Dutchess Water Line tap water safe to drink?
EPA monitoring detected 12 contaminants in Central Dutchess Water Line's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Central Dutchess Water Line's water?
EPA monitoring detected Bromodichloromethane, Chloroform, Trichloroacetic Acid, Dichloroacetic Acid, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does Central Dutchess Water Line serve?
Central Dutchess Water Line reports serving 400 people in New York, per its EPA record.
Has Central Dutchess Water Line had any water quality violations?
The EPA has 2 violations on file for Central Dutchess Water Line, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.