Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 1998-11-01 → 1998-11-30 |
| TT | Health-based | Resolved | 1996-07-01 → 1996-07-31 |
| TT | Health-based | Resolved | 1995-11-01 → 1995-11-30 |
| TT | Health-based | Resolved | 1995-10-01 → 1995-10-31 |
| TT | Health-based | Resolved | 1995-08-01 → 1995-08-31 |
| MCL | Health-based | Resolved | 1995-07-01 → 1995-09-30 |
| MCL | Health-based | Resolved | 1995-01-01 → 1995-03-31 |
| TT | Health-based | Resolved | 1994-06-01 → 1994-06-30 |
| TT | Health-based | Resolved | 1994-05-01 → 1994-05-31 |
| TT | Health-based | Resolved | 1994-04-01 → 1994-04-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Chloroform | 87.095 µg/L No EPA limit set
worst single sample: 122 µg/L | 62/62 | SYR4 | 2012–2019 |
| TTHM | 113.025 µg/L 141% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 141 µg/L | 62/62 | SYR4 | 2012–2019 |
| Bromodichloromethane | 23.6 µg/L No EPA limit set
worst single sample: 29.7 µg/L | 61/61 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 53.895 µg/L 90% of the EPA limit 60 µg/L
worst single sample: 101.5 µg/L | 58/62 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 29.7 µg/L No EPA limit set
worst single sample: 38 µg/L | 54/61 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 22.38 µg/L No EPA limit set
worst single sample: 36.5 µg/L | 53/62 | SYR4 | 2012–2019 |
| Dibromochloromethane | 7.722 µg/L No EPA limit set
worst single sample: 12.2 µg/L | 42/59 | SYR4 | 2012–2019 |
| Lead | 0.0010 mg/L 6.7% of the EPA limit 0.0150 mg/L | 13/13 | LCR | 2025 |
| Monobromoacetic Acid | 34.65 µg/L No EPA limit set
worst single sample: 34.8 µg/L | 11/62 | SYR4 | 2012–2019 |
| Bromoform | 1.174 µg/L No EPA limit set
worst single sample: 1.18 µg/L | 5/62 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.975 µg/L No EPA limit set
worst single sample: 2 µg/L | 2/62 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 2 µg/L No EPA limit set | 1/62 | SYR4 | 2012–2019 |
Utility contact
Frequently asked questions about Staatsburg Water
Is Staatsburg Water tap water safe to drink?
EPA monitoring detected 12 contaminants in Staatsburg Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Staatsburg Water's water?
EPA monitoring detected Chloroform, TTHM, Bromodichloromethane, Total Haloacetic Acids (HAA5), Trichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Staatsburg Water serve?
Staatsburg Water reports serving 1,164 people in New York, per its EPA record.
Has Staatsburg Water had any water quality violations?
The EPA has 44 violations on file for Staatsburg Water, of which 19 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.