← New York

Tap water quality report

Greene Village

EPA monitoring tested this supplier for 73 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

73
contaminants tested
19
detected
1,800
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Chenango

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
26
violations on file
0
still open
ViolationTypeStatusPeriod
MON Monitoring Resolved 2022-04-01 → 2022-04-30
MON Monitoring Resolved 2022-04-01 → 2022-04-30
MON Monitoring Resolved 2022-04-01 → 2022-04-30
MON Monitoring Resolved 2022-04-01 → 2022-04-30
MR Monitoring Resolved 2015-02-01 → 2015-02-28
MR Monitoring Resolved 2015-02-01 → 2015-02-28
MR Monitoring Resolved 2015-02-01 → 2015-02-28
MR Monitoring Resolved 2015-02-01 → 2015-02-28
Other Monitoring Resolved 2009-12-01 → 2009-12-31
Other Monitoring Resolved 2009-12-01 → 2009-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2647.5 µg/L 26%
of the EPA limit 10000 µg/L
worst single sample: 2700 µg/L
28/48 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
TTHM
31.365 µg/L 39%
of the EPA limit 80 µg/L
worst single sample: 31.5 µg/L
10/12 SYR4 2013–2019
Nitrate-Nitrite
2724 µg/L 27%
of the EPA limit 10000 µg/L
worst single sample: 2740 µg/L
9/9 SYR4 2017–2019
Bromodichloromethane
6.8825 µg/L
No EPA limit set
worst single sample: 6.9 µg/L
8/10 SYR4 2013–2019
Bromoform
12.57 µg/L
No EPA limit set
worst single sample: 13.9 µg/L
8/10 SYR4 2013–2019
Dibromochloromethane
10.965 µg/L
No EPA limit set
worst single sample: 11 µg/L
8/10 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
5.002 µg/L 8.3%
of the EPA limit 60 µg/L
worst single sample: 5.1 µg/L
8/12 SYR4 2013–2019
Chloroform
3.599 µg/L
No EPA limit set
worst single sample: 3.62 µg/L
7/10 SYR4 2013–2019
Barium
228.5 µg/L 11%
of the EPA limit 2000 µg/L
worst single sample: 245 µg/L
4/6 SYR4 2014–2017
Dibromoacetic Acid
2.065 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
4/10 SYR4 2013–2019
Dichloroacetic Acid
1.483 µg/L
No EPA limit set
worst single sample: 1.63 µg/L
4/10 SYR4 2013–2019
Combined Radium (-226 And -228)
0.5050 pCi/L 10%
of the EPA limit 5 pCi/L
worst single sample: 0.5200 pCi/L
3/3 SYR4 2014–2017
Trichloroacetic Acid
3.005 µg/L
No EPA limit set
worst single sample: 3.19 µg/L
3/10 SYR4 2013–2019
Arsenic
6.5 µg/L 65%
of the EPA limit 10 µg/L
1/6 SYR4 2014–2017
Lead
10.3 µg/L 69%
of the EPA limit 15 µg/L
1/3 SYR4 2014
Monobromoacetic Acid
0.7200 µg/L
No EPA limit set
1/10 SYR4 2013–2019
Monochloroacetic Acid
1.1 µg/L
No EPA limit set
1/10 SYR4 2013–2019
Nitrite
426 µg/L 43%
of the EPA limit 1000 µg/L
1/9 SYR4 2017–2019
54 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DUMONDE, JESSUP
Phone
607-656-4540
Email
[email protected]

Frequently asked questions about Greene Village

Is Greene Village tap water safe to drink?

EPA monitoring detected 19 contaminants in Greene Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Greene Village's water?

EPA monitoring detected Nitrate, Lead, TTHM, Nitrate-Nitrite, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Greene Village serve?

Greene Village reports serving 1,800 people in New York, per its EPA record.

Has Greene Village had any water quality violations?

The EPA has 26 violations on file for Greene Village, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.