← New York

Tap water quality report

Newtown Creek Community Inc.

EPA monitoring tested this supplier for 73 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

73
contaminants tested
13
detected
120
people served
6
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Chemung

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

6
health-based violations
34
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2011-08-01 → 2011-08-31
MCL Health-based Resolved 2011-08-01 → 2011-08-31
MCL Health-based Resolved 2011-08-01 → 2011-08-31
MCL Health-based Resolved 2011-08-01 → 2011-08-31
MCL Health-based Resolved 2011-08-01 → 2011-08-31
MCL Health-based Resolved 2011-08-01 → 2011-08-31
MON Monitoring Resolved 2023-05-01 → 2023-05-31
MON Monitoring Resolved 2023-05-01 → 2023-05-31
MON Monitoring Resolved 2023-05-01 → 2023-05-31
MON Monitoring Resolved 2023-05-01 → 2023-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0030 mg/L 20%
of the EPA limit 0.0150 mg/L
12/12 LCR 2025
Nitrate
1050 µg/L 11%
of the EPA limit 10000 µg/L
12/16 SYR4 2012–2019
Bromodichloromethane
1.7915 µg/L
No EPA limit set
worst single sample: 2 µg/L
4/5 SYR4 2012–2019
Nitrate-Nitrite
966.75 µg/L 9.7%
of the EPA limit 10000 µg/L
worst single sample: 1050 µg/L
4/6 SYR4 2014–2019
Barium
124.8 µg/L 6.2%
of the EPA limit 2000 µg/L
worst single sample: 126 µg/L
3/3 SYR4 2012–2018
Dibromochloromethane
2.138 µg/L
No EPA limit set
worst single sample: 2.3 µg/L
3/5 SYR4 2012–2019
TTHM
6.681 µg/L 8.4%
of the EPA limit 80 µg/L
worst single sample: 7.28 µg/L
3/3 SYR4 2013–2019
Bromoform
0.9940 µg/L
No EPA limit set
worst single sample: 1 µg/L
2/4 SYR4 2013–2019
Dibromoacetic Acid
1.77 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
2/3 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
4.525 µg/L 7.5%
of the EPA limit 60 µg/L
worst single sample: 4.7 µg/L
2/3 SYR4 2013–2019
Chloroform
2.1 µg/L
No EPA limit set
1/4 SYR4 2013–2019
Dichloroacetic Acid
2.4 µg/L
No EPA limit set
1/3 SYR4 2013–2019
Trichloroacetic Acid
0.5100 µg/L
No EPA limit set
1/3 SYR4 2013–2019
60 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDinosebEthylene DibromideEndrinEthylbenzeneFluorideGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
KUZMISKY, TAMMY
Phone
585-262-3113
Email
[email protected]

Frequently asked questions about Newtown Creek Community Inc.

Is Newtown Creek Community Inc. tap water safe to drink?

EPA monitoring detected 13 contaminants in Newtown Creek Community Inc.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Newtown Creek Community Inc.'s water?

EPA monitoring detected Lead, Nitrate, Bromodichloromethane, Nitrate-Nitrite, Barium, and others. The full list with the level and data source for each is above.

How many people does Newtown Creek Community Inc. serve?

Newtown Creek Community Inc. reports serving 120 people in New York, per its EPA record.

Has Newtown Creek Community Inc. had any water quality violations?

The EPA has 34 violations on file for Newtown Creek Community Inc., of which 6 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.