← New York

Tap water quality report

Hillcrest Wd #1

EPA monitoring tested this supplier for 45 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

45
contaminants tested
12
detected
2,100
people served
1
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Broome

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

1
health-based violations
65
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1994-09-01 → 1994-09-30
MR Monitoring Resolved 2025-01-01 → 2025-12-31
MR Monitoring Resolved 2025-01-01 → 2025-12-31
MR Monitoring Resolved 2025-01-01 → 2025-12-31
MR Monitoring Resolved 2025-01-01 → 2025-12-31
MR Monitoring Resolved 2025-01-01 → 2025-12-31
MR Monitoring Resolved 2025-01-01 → 2025-12-31
MR Monitoring Resolved 2025-01-01 → 2025-12-31
MR Monitoring Resolved 2025-01-01 → 2025-12-31
MR Monitoring Resolved 2025-01-01 → 2025-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1832.5 µg/L 18%
of the EPA limit 10000 µg/L
worst single sample: 1840 µg/L
24/44 SYR4 2012–2019
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
11/11 LCR 2025
Bromoform
2.595 µg/L
No EPA limit set
worst single sample: 3 µg/L
6/6 SYR4 2013–2019
Dibromochloromethane
2.2525 µg/L
No EPA limit set
worst single sample: 2.37 µg/L
6/6 SYR4 2013–2019
TTHM
5.05 µg/L 6.3%
of the EPA limit 80 µg/L
worst single sample: 5.5 µg/L
6/6 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
1.0075 µg/L 1.7%
of the EPA limit 60 µg/L
worst single sample: 1.01 µg/L
6/6 SYR4 2013–2019
Dibromoacetic Acid
0.9500 µg/L
No EPA limit set
worst single sample: 1 µg/L
5/6 SYR4 2013–2019
Barium
208.55 µg/L 10%
of the EPA limit 2000 µg/L
worst single sample: 209 µg/L
2/2 SYR4 2014–2017
Bromodichloromethane
0.5980 µg/L
No EPA limit set
worst single sample: 0.6000 µg/L
2/6 SYR4 2013–2019
Arsenic
1 µg/L 10%
of the EPA limit 10 µg/L
1/2 SYR4 2014–2017
Combined Radium (-226 And -228)
1.32 pCi/L 26%
of the EPA limit 5 pCi/L
1/1 SYR4 2016
Monochloroacetic Acid
1.01 µg/L
No EPA limit set
1/6 SYR4 2013–2019
33 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChloroformChromiumDichloromethaneDichloroacetic AcidEthylbenzeneFluorideMercuryMonobromoacetic AcidSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
STARLEY, GREG
Phone
607-724-3786

Frequently asked questions about Hillcrest Wd #1

Is Hillcrest Wd #1 tap water safe to drink?

EPA monitoring detected 12 contaminants in Hillcrest Wd #1's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Hillcrest Wd #1's water?

EPA monitoring detected Nitrate, Lead, Bromoform, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Hillcrest Wd #1 serve?

Hillcrest Wd #1 reports serving 2,100 people in New York, per its EPA record.

Has Hillcrest Wd #1 had any water quality violations?

The EPA has 65 violations on file for Hillcrest Wd #1, of which 1 is health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.