← New York

Tap water quality report

Latham Water District

EPA monitoring tested this supplier for 103 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

103
contaminants tested
16
detected
85,590
people served
3
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Albany

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
26
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2004-07-01 → 2004-09-30
MCL Health-based Resolved 2004-07-01 → 2004-09-30
MCL Health-based Resolved 2004-07-01 → 2004-09-30
MR Monitoring Resolved 1994-06-01 → 1994-06-30
MR Monitoring Resolved 1994-06-01 → 1994-06-30
MR Monitoring Resolved 1994-05-01 → 1994-05-31
MR Monitoring Resolved 1994-05-01 → 1994-05-31
MR Monitoring Resolved 1994-03-01 → 1994-03-31
MR Monitoring Resolved 1994-03-01 → 1994-03-31
MR Monitoring Resolved 1994-03-01 → 1994-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
52.79 µg/L
No EPA limit set
worst single sample: 72.2 µg/L
142/142 SYR4 2014–2019
Dichloroacetic Acid
18.475 µg/L
No EPA limit set
worst single sample: 33 µg/L
142/142 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
43.495 µg/L 72%
of the EPA limit 60 µg/L
worst single sample: 63.9 µg/L
142/142 SYR4 2014–2019
Trichloroacetic Acid
23.95 µg/L
No EPA limit set
worst single sample: 32.3 µg/L
142/142 SYR4 2014–2019
Bromodichloromethane
13.8 µg/L
No EPA limit set
worst single sample: 14.7 µg/L
141/141 SYR4 2014–2019
TTHM
69.9 µg/L 87%
of the EPA limit 80 µg/L
worst single sample: 100 µg/L
141/141 SYR4 2014–2019
Dibromochloromethane
5.53 µg/L
No EPA limit set
worst single sample: 13.9 µg/L
130/141 SYR4 2014–2019
Monochloroacetic Acid
8.1225 µg/L
No EPA limit set
worst single sample: 8.6 µg/L
58/142 SYR4 2014–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
16/16 LCR 2024
Nitrate
700 µg/L 7%
of the EPA limit 10000 µg/L
14/14 SYR4 2012–2019
Dibromoacetic Acid
2.2 µg/L
No EPA limit set
7/142 SYR4 2014–2019
Barium
30.32 µg/L 1.5%
of the EPA limit 2000 µg/L
worst single sample: 31 µg/L
5/7 SYR4 2012–2019
Monobromoacetic Acid
3.85 µg/L
No EPA limit set
worst single sample: 4 µg/L
4/142 SYR4 2014–2019
Combined Radium (-226 And -228)
0.3640 pCi/L 7.3%
of the EPA limit 5 pCi/L
1/1 SYR4 2017
Combined Uranium
0.0230 µg/L 0.1%
of the EPA limit 30 µg/L
1/1 SYR4 2017
Gross Alpha, Excl. Radon And U
1.3 pCi/L 8.7%
of the EPA limit 15 pCi/L
1/1 SYR4 2017
87 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SEAVER, DANIEL
Phone
518-786-7338
Email
[email protected]

Frequently asked questions about Latham Water District

Is Latham Water District tap water safe to drink?

EPA monitoring detected 16 contaminants in Latham Water District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Latham Water District's water?

EPA monitoring detected Chloroform, Dichloroacetic Acid, Total Haloacetic Acids (HAA5), Trichloroacetic Acid, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Latham Water District serve?

Latham Water District reports serving 85,590 people in New York, per its EPA record.

Has Latham Water District had any water quality violations?

The EPA has 26 violations on file for Latham Water District, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.