← Nevada

Tap water quality report

Nellis Air Force Base

EPA monitoring tested this supplier for 112 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

112
contaminants tested
23
detected
19,081
people served
38
health-based violations
Water source
SWP
Ownership
Federal government
Counties served
Clark

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

38
health-based violations
42
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2025-07-01 → 2025-09-30
MCL Health-based Resolved 2025-07-01 → 2025-09-30
MCL Health-based Resolved 2025-07-01 → 2025-09-30
MCL Health-based Resolved 2025-07-01 → 2025-09-30
MCL Health-based Resolved 2017-07-01 → 2017-09-30
MCL Health-based Resolved 2017-07-01 → 2017-09-30
MCL Health-based Resolved 2017-07-01 → 2017-09-30
MCL Health-based Resolved 2017-07-01 → 2017-09-30
MCL Health-based Resolved 2017-04-01 → 2017-06-30
MCL Health-based Resolved 2017-04-01 → 2017-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Fluoride
746.1 µg/L 19%
of the EPA limit 4000 µg/L
worst single sample: 764 µg/L
107/107 SYR4 2012–2019
Bromodichloromethane
25.64 µg/L
No EPA limit set
worst single sample: 33.3 µg/L
99/99 SYR4 2012–2019
Bromoform
2.31 µg/L
No EPA limit set
worst single sample: 2.9 µg/L
99/99 SYR4 2012–2019
Chloroform
46.09 µg/L
No EPA limit set
worst single sample: 69 µg/L
99/99 SYR4 2012–2019
Dibromochloromethane
16.9 µg/L
No EPA limit set
worst single sample: 17.9 µg/L
99/99 SYR4 2012–2019
TTHM
89.63 µg/L 112%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 122.5 µg/L
99/99 SYR4 2012–2019
Dichloroacetic Acid
23.6 µg/L
No EPA limit set
worst single sample: 26 µg/L
98/99 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
40.015 µg/L 67%
of the EPA limit 60 µg/L
worst single sample: 47.5 µg/L
98/99 SYR4 2012–2019
Trichloroacetic Acid
12.45 µg/L
No EPA limit set
worst single sample: 14 µg/L
96/99 SYR4 2012–2019
Dibromoacetic Acid
4.4 µg/L
No EPA limit set
worst single sample: 10.5 µg/L
85/99 SYR4 2012–2019
Arsenic
3.245 µg/L 32%
of the EPA limit 10 µg/L
worst single sample: 5.3 µg/L
52/52 SYR4 2012–2019
Copper
1316 µg/L 101%
of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 1790 µg/L
32/38 SYR4 2014–2019
Lead
7.725 µg/L 52%
of the EPA limit 15 µg/L
worst single sample: 19 µg/L
32/38 SYR4 2014–2019
Nitrate
740 µg/L 7.4%
of the EPA limit 10000 µg/L
worst single sample: 800 µg/L
26/26 SYR4 2012–2019
Lead
0.0067 mg/L 44%
of the EPA limit 0.0150 mg/L
21/21 LCR 2025
Monochloroacetic Acid
2.9 µg/L
No EPA limit set
worst single sample: 3 µg/L
21/99 SYR4 2012–2019
Monobromoacetic Acid
7.14 µg/L
No EPA limit set
worst single sample: 10 µg/L
14/99 SYR4 2012–2019
Combined Uranium
3.6 µg/L 12%
of the EPA limit 30 µg/L
10/10 SYR4 2013–2019
Selenium
2.43 µg/L 4.9%
of the EPA limit 50 µg/L
worst single sample: 2.7 µg/L
10/10 SYR4 2014–2019
Barium
120 µg/L 6%
of the EPA limit 2000 µg/L
8/8 SYR4 2014–2019
Nitrate-Nitrite
552.3 µg/L 5.5%
of the EPA limit 10000 µg/L
worst single sample: 560 µg/L
8/8 SYR4 2014–2019
Lithium
58.4 µg/L
No EPA limit set
6/8 UCMR-5 2024
Gross Alpha, Excl. Radon And U
3.875 pCi/L 26%
of the EPA limit 15 pCi/L
worst single sample: 4 pCi/L
2/5 SYR4 2014–2017
89 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PERKINS, CHRISTOPHER
Phone
702-652-8897
Email
[email protected]

Frequently asked questions about Nellis Air Force Base

Is Nellis Air Force Base tap water safe to drink?

EPA monitoring detected 23 contaminants in Nellis Air Force Base's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Nellis Air Force Base's water?

EPA monitoring detected Fluoride, Bromodichloromethane, Bromoform, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Nellis Air Force Base serve?

Nellis Air Force Base reports serving 19,081 people in Nevada, per its EPA record.

Has Nellis Air Force Base had any water quality violations?

The EPA has 42 violations on file for Nellis Air Force Base, of which 38 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.