← Nevada

Tap water quality report

Harris Springs Ranch

EPA monitoring tested this supplier for 83 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

83
contaminants tested
11
detected
40
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Clark

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
29
violations on file
0
still open
ViolationTypeStatusPeriod
RPT Monitoring Resolved 2023-02-01
RPT Monitoring Resolved 2023-02-01
RPT Monitoring Resolved 2023-02-01
RPT Monitoring Resolved 2023-02-01
RPT Monitoring Resolved 2023-02-01
RPT Monitoring Resolved 2023-01-01
RPT Monitoring Resolved 2023-01-01
RPT Monitoring Resolved 2023-01-01
RPT Monitoring Resolved 2023-01-01
RPT Monitoring Resolved 2023-01-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0019 mg/L 12%
of the EPA limit 0.0150 mg/L
14/14 LCR 2023
Nitrate
450 µg/L 4.5%
of the EPA limit 10000 µg/L
12/18 SYR4 2012–2019
Copper
35.8 µg/L 2.8%
of the EPA limit 1300 µg/L
worst single sample: 36 µg/L
5/10 SYR4 2013–2019
Combined Uranium
2.5 µg/L 8.3%
of the EPA limit 30 µg/L
4/6 SYR4 2012–2019
Fluoride
447 µg/L 11%
of the EPA limit 4000 µg/L
worst single sample: 450 µg/L
4/4 SYR4 2013–2019
Nitrate-Nitrite
334.5 µg/L 3.3%
of the EPA limit 10000 µg/L
worst single sample: 360 µg/L
4/4 SYR4 2013–2019
Bromoform
2.99 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
3/10 SYR4 2013–2019
TTHM
4.092 µg/L 5.1%
of the EPA limit 80 µg/L
worst single sample: 4.18 µg/L
3/5 SYR4 2014–2019
Barium
49.85 µg/L 2.5%
of the EPA limit 2000 µg/L
worst single sample: 50 µg/L
2/2 SYR4 2016–2019
Dibromochloromethane
1.29 µg/L
No EPA limit set
worst single sample: 1.3 µg/L
2/10 SYR4 2013–2019
Toluene
1.8 µg/L 0.2%
of the EPA limit 1000 µg/L
1/7 SYR4 2013–2019
72 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ALEXANDER, SCOTT
Phone
702-385-2090
Email
[email protected]

Frequently asked questions about Harris Springs Ranch

Is Harris Springs Ranch tap water safe to drink?

EPA monitoring detected 11 contaminants in Harris Springs Ranch's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Harris Springs Ranch's water?

EPA monitoring detected Lead, Nitrate, Copper, Combined Uranium, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Harris Springs Ranch serve?

Harris Springs Ranch reports serving 40 people in Nevada, per its EPA record.

Has Harris Springs Ranch had any water quality violations?

The EPA has 29 violations on file for Harris Springs Ranch, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.