← Nevada

Tap water quality report

Storey County Water District

EPA monitoring tested this supplier for 83 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

83
contaminants tested
14
detected
1,420
people served
5
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Storey

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
81
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2010-04-01 → 2010-06-30
MCL Health-based Resolved 2010-04-01 → 2010-06-30
MCL Health-based Resolved 2010-04-01 → 2010-06-30
MCL Health-based Resolved 2010-04-01 → 2010-06-30
TT Health-based Resolved 1992-01-01 → 1998-03-01
RPT Monitoring Resolved 2022-09-01
RPT Monitoring Resolved 2022-09-01
RPT Monitoring Resolved 2022-09-01
RPT Monitoring Resolved 2021-03-11
RPT Monitoring Resolved 2021-03-11

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
63.9 µg/L
No EPA limit set
worst single sample: 88 µg/L
83/84 SYR4 2012–2019
TTHM
66.71 µg/L 83%
of the EPA limit 80 µg/L
worst single sample: 91 µg/L
82/82 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
64.6 µg/L 108%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 76 µg/L
82/82 SYR4 2012–2019
Trichloroacetic Acid
39.95 µg/L
No EPA limit set
worst single sample: 49 µg/L
82/82 SYR4 2012–2019
Dichloroacetic Acid
25 µg/L
No EPA limit set
worst single sample: 29 µg/L
80/82 SYR4 2012–2019
Bromodichloromethane
2.14 µg/L
No EPA limit set
worst single sample: 2.7 µg/L
65/84 SYR4 2012–2019
Monochloroacetic Acid
11.15 µg/L
No EPA limit set
worst single sample: 12 µg/L
18/82 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
9/9 LCR 2023
Monobromoacetic Acid
12.85 µg/L
No EPA limit set
worst single sample: 13 µg/L
4/82 SYR4 2012–2019
Dibromoacetic Acid
3.775 µg/L
No EPA limit set
worst single sample: 3.9 µg/L
2/82 SYR4 2012–2019
Nitrate
110 µg/L 1.1%
of the EPA limit 10000 µg/L
2/16 SYR4 2012–2019
Dalapon
0.1100 µg/L 0.1%
of the EPA limit 200 µg/L
1/3 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
0.8200 µg/L 14%
of the EPA limit 6 µg/L
1/9 SYR4 2012–2019
Dibromochloromethane
22 µg/L
No EPA limit set
1/84 SYR4 2012–2019
69 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WIERZBICKI, JASON
Phone
775-847-0958
Email
[email protected]

Frequently asked questions about Storey County Water District

Is Storey County Water District tap water safe to drink?

EPA monitoring detected 14 contaminants in Storey County Water District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Storey County Water District's water?

EPA monitoring detected Chloroform, TTHM, Total Haloacetic Acids (HAA5), Trichloroacetic Acid, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Storey County Water District serve?

Storey County Water District reports serving 1,420 people in Nevada, per its EPA record.

Has Storey County Water District had any water quality violations?

The EPA has 81 violations on file for Storey County Water District, of which 5 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.