Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2006-06-01 → 2006-06-30 |
| TT | Health-based | Resolved | 2006-06-01 → 2006-06-30 |
| TT | Health-based | Resolved | 2006-06-01 → 2006-06-30 |
| TT | Health-based | Resolved | 2006-06-01 → 2006-06-30 |
| MR | Monitoring | Resolved | 2022-05-01 → 2022-07-31 |
| MR | Monitoring | Resolved | 2022-05-01 → 2022-07-31 |
| MR | Monitoring | Resolved | 2022-05-01 → 2022-07-31 |
| MR | Monitoring | Resolved | 2022-05-01 → 2022-07-31 |
| MR | Monitoring | Resolved | 2022-05-01 → 2022-07-31 |
| MR | Monitoring | Resolved | 2022-05-01 → 2022-07-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Chloroform | 21 µg/L No EPA limit set
worst single sample: 23 µg/L | 60/61 | SYR4 | 2012–2019 |
| Bromodichloromethane | 3.4 µg/L No EPA limit set
worst single sample: 2300 µg/L | 55/61 | SYR4 | 2012–2019 |
| TTHM | 25.04 µg/L 31% of the EPA limit 80 µg/L
worst single sample: 28.4 µg/L | 53/53 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 7.46 µg/L 12% of the EPA limit 60 µg/L
worst single sample: 11 µg/L | 53/56 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 3.225 µg/L No EPA limit set
worst single sample: 3.8 µg/L | 52/56 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 5.085 µg/L No EPA limit set
worst single sample: 6.6 µg/L | 50/56 | SYR4 | 2012–2019 |
| Dibromochloromethane | 1.555 µg/L No EPA limit set
worst single sample: 960 µg/L | 44/61 | SYR4 | 2012–2019 |
| Bromate | 3.525 µg/L 35% of the EPA limit 10 µg/L
worst single sample: 9.9 µg/L | 34/65 | SYR4 | 2012–2019 |
| Lead | 0.0014 mg/L 9.3% of the EPA limit 0.0150 mg/L | 9/9 | LCR | 2025 |
| Barium | 13 µg/L 0.7% of the EPA limit 2000 µg/L | 7/8 | SYR4 | 2012–2019 |
| Copper | 13.4 µg/L 1% of the EPA limit 1300 µg/L
worst single sample: 14 µg/L | 7/35 | SYR4 | 2012–2019 |
| Lead | 2.685 µg/L 18% of the EPA limit 15 µg/L
worst single sample: 2.7 µg/L | 4/28 | SYR4 | 2012–2019 |
| Arsenic | 2.09 µg/L 21% of the EPA limit 10 µg/L
worst single sample: 2.1 µg/L | 3/8 | SYR4 | 2012–2019 |
| Tetrachloroethylene | 0.5600 µg/L 11% of the EPA limit 5 µg/L | 1/9 | SYR4 | 2012–2019 |
99 contaminants tested, none detected
Utility contact
Frequently asked questions about Incline Village Gid
Is Incline Village Gid tap water safe to drink?
EPA monitoring detected 14 contaminants in Incline Village Gid's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Incline Village Gid's water?
EPA monitoring detected Chloroform, Bromodichloromethane, TTHM, Total Haloacetic Acids (HAA5), Trichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Incline Village Gid serve?
Incline Village Gid reports serving 9,313 people in Nevada, per its EPA record.
Has Incline Village Gid had any water quality violations?
The EPA has 32 violations on file for Incline Village Gid, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.