← New Jersey

Tap water quality report

Township of Blairstown Dpw

EPA monitoring tested this supplier for 51 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

51
contaminants tested
20
detected
800
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Warren

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
58
violations on file
1
still open
ViolationTypeStatusPeriod
MR Monitoring Unaddressed 2023-12-30
MR Monitoring Resolved 2020-12-30
MR Monitoring Resolved 2020-12-30
Other Monitoring Resolved 2019-07-01
Other Monitoring Resolved 2019-07-01
MR Monitoring Resolved 2019-01-01 → 2019-03-31
MR Monitoring Resolved 2019-01-01 → 2019-03-31
MR Monitoring Resolved 2019-01-01 → 2019-03-31
MR Monitoring Resolved 2019-01-01 → 2019-03-31
RPT Monitoring Resolved 2017-06-11

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
148.75 µg/L 11%
of the EPA limit 1300 µg/L
worst single sample: 163 µg/L
20/23 SYR4 2012–2018
Chloroform
13.4 µg/L
No EPA limit set
worst single sample: 18.3 µg/L
15/16 SYR4 2012–2019
Bromodichloromethane
7.11 µg/L
No EPA limit set
worst single sample: 7.5 µg/L
14/16 SYR4 2012–2019
Lead
0.0059 mg/L 40%
of the EPA limit 0.0150 mg/L
14/14 LCR 2023
TTHM
28.14 µg/L 35%
of the EPA limit 80 µg/L
worst single sample: 30 µg/L
13/13 SYR4 2012–2019
Dibromochloromethane
5.1 µg/L
No EPA limit set
worst single sample: 6.2 µg/L
12/16 SYR4 2012–2019
Lead
1.88 µg/L 13%
of the EPA limit 15 µg/L
worst single sample: 2.6 µg/L
10/20 SYR4 2014–2017
Dichloroacetic Acid
3.225 µg/L
No EPA limit set
worst single sample: 3.39 µg/L
6/13 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
7.4875 µg/L 12%
of the EPA limit 60 µg/L
worst single sample: 7.98 µg/L
6/13 SYR4 2012–2019
Bromoform
1.782 µg/L
No EPA limit set
worst single sample: 1.9 µg/L
5/16 SYR4 2012–2019
Dibromoacetic Acid
1.4745 µg/L
No EPA limit set
worst single sample: 1.53 µg/L
4/13 SYR4 2012–2019
Nitrate
513 µg/L 5.1%
of the EPA limit 10000 µg/L
4/12 SYR4 2012–2017
Barium
84.75 µg/L 4.2%
of the EPA limit 2000 µg/L
worst single sample: 86 µg/L
3/3 SYR4 2012–2018
Trichloroacetic Acid
1.071 µg/L
No EPA limit set
worst single sample: 1.09 µg/L
3/13 SYR4 2012–2019
Arsenic
0.6200 µg/L 6.2%
of the EPA limit 10 µg/L
2/3 SYR4 2012–2018
Chromium
0.9745 µg/L 1%
of the EPA limit 100 µg/L
worst single sample: 1 µg/L
2/3 SYR4 2012–2018
Monochloroacetic Acid
3.997 µg/L
No EPA limit set
worst single sample: 4.15 µg/L
2/13 SYR4 2012–2019
Selenium
2.043 µg/L 4.1%
of the EPA limit 50 µg/L
worst single sample: 2.1 µg/L
2/3 SYR4 2012–2018
Cyanide
5 µg/L 2.5%
of the EPA limit 200 µg/L
1/3 SYR4 2012–2018
Mercury
0.0410 µg/L 2.1%
of the EPA limit 2 µg/L
1/3 SYR4 2012–2018
31 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbon TetrachlorideCombined Radium (-226 And -228)DichloromethaneEthylene DibromideEthylbenzeneFluorideMonobromoacetic AcidNitrate-NitriteStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SCHWARTZ, ALBERT
Phone
908-268-6983

Frequently asked questions about Township of Blairstown Dpw

Is Township of Blairstown Dpw tap water safe to drink?

EPA monitoring detected 20 contaminants in Township of Blairstown Dpw's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Township of Blairstown Dpw's water?

EPA monitoring detected Copper, Chloroform, Bromodichloromethane, Lead, TTHM, and others. The full list with the level and data source for each is above.

How many people does Township of Blairstown Dpw serve?

Township of Blairstown Dpw reports serving 800 people in New Jersey, per its EPA record.

Has Township of Blairstown Dpw had any water quality violations?

The EPA has 58 violations on file for Township of Blairstown Dpw, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.