← New Jersey

Tap water quality report

Lake Stockholm Inc

EPA monitoring tested this supplier for 52 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

52
contaminants tested
12
detected
300
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Sussex

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
112
violations on file
1
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
MR Monitoring Archived 2024-07-01 → 2024-09-30
MR Monitoring Archived 2024-07-01 → 2024-09-30
RPT Monitoring Unaddressed 2024-01-11
MON Monitoring Archived 2023-12-01 → 2023-12-31
MON Monitoring Archived 2023-12-01 → 2023-12-31
MON Monitoring Archived 2023-12-01 → 2023-12-31
Other Monitoring Resolved 2023-10-28
Other Monitoring Resolved 2023-10-28

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
8878.5 µg/L 89%
of the EPA limit 10000 µg/L
worst single sample: 9190 µg/L
28/28 SYR4 2012–2019
Lead
0.0053 mg/L 36%
of the EPA limit 0.0150 mg/L
24/24 LCR 2025
Copper
326.6 µg/L 25%
of the EPA limit 1300 µg/L
worst single sample: 419 µg/L
15/18 SYR4 2012–2019
Lead
10.653 µg/L 71%
of the EPA limit 15 µg/L
worst single sample: 11.1 µg/L
7/15 SYR4 2013–2019
Barium
312.7 µg/L 16%
of the EPA limit 2000 µg/L
worst single sample: 321 µg/L
2/3 SYR4 2012–2018
Bromoform
1.6505 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
2/11 SYR4 2012–2019
Dibromoacetic Acid
1.277 µg/L
No EPA limit set
worst single sample: 1.31 µg/L
2/8 SYR4 2012–2019
TTHM
2.9805 µg/L 3.7%
of the EPA limit 80 µg/L
worst single sample: 3.1 µg/L
2/8 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
1.277 µg/L 2.1%
of the EPA limit 60 µg/L
worst single sample: 1.31 µg/L
2/8 SYR4 2012–2019
Cadmium
0.0820 µg/L 1.6%
of the EPA limit 5 µg/L
1/3 SYR4 2012–2018
Dibromochloromethane
1.38 µg/L
No EPA limit set
1/11 SYR4 2012–2019
Thallium, Total
1.66 µg/L 83%
of the EPA limit 2 µg/L
1/3 SYR4 2012–2018
40 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalArsenicAsbestosBenzeneBeryllium, TotalBromodichloromethaneChlorobenzeneCyanideCarbon TetrachlorideChloroformChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDichloroacetic AcidEthylene DibromideEthylbenzeneFluorideMercuryMonobromoacetic AcidMonochloroacetic AcidSeleniumStyreneTetrachloroethyleneTolueneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
POSPIECH, STEVE
Phone
732-721-1202

Frequently asked questions about Lake Stockholm Inc

Is Lake Stockholm Inc tap water safe to drink?

EPA monitoring detected 12 contaminants in Lake Stockholm Inc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lake Stockholm Inc's water?

EPA monitoring detected Nitrate, Lead, Copper, Lead, Barium, and others. The full list with the level and data source for each is above.

How many people does Lake Stockholm Inc serve?

Lake Stockholm Inc reports serving 300 people in New Jersey, per its EPA record.

Has Lake Stockholm Inc had any water quality violations?

The EPA has 112 violations on file for Lake Stockholm Inc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.