← New Jersey

Tap water quality report

Culver Lake Water Company

EPA monitoring tested this supplier for 50 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

50
contaminants tested
15
detected
40
people served
6
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Sussex

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

6
health-based violations
255
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 1998-10-01 → 1998-10-31
MCL Health-based Resolved 1998-09-01 → 1998-09-30
MCL Health-based Resolved 1998-08-01 → 1998-08-31
MCL Health-based Resolved 1998-07-01 → 1998-07-31
MCL Health-based Resolved 1997-09-01 → 1997-09-30
MCL Health-based Resolved 1997-08-01 → 1997-08-31
MR Monitoring Archived 2014-01-01 → 2014-03-31
MR Monitoring Resolved 2007-11-01 → 2007-11-30
MR Monitoring Resolved 2007-11-01 → 2007-11-30
MR Monitoring Resolved 2007-11-01 → 2007-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0040 mg/L 26%
of the EPA limit 0.0150 mg/L
14/14 LCR 2023
Copper
658.8 µg/L 51%
of the EPA limit 1300 µg/L
worst single sample: 708 µg/L
13/13 SYR4 2012–2018
Chloroform
1.545 µg/L
No EPA limit set
worst single sample: 1.6 µg/L
12/12 SYR4 2012–2019
TTHM
10.24 µg/L 13%
of the EPA limit 80 µg/L
worst single sample: 13 µg/L
9/9 SYR4 2012–2019
Bromodichloromethane
1.815 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
8/12 SYR4 2012–2019
Dibromochloromethane
2.995 µg/L
No EPA limit set
worst single sample: 3.8 µg/L
8/12 SYR4 2012–2019
Lead
7.25 µg/L 48%
of the EPA limit 15 µg/L
worst single sample: 9 µg/L
8/10 SYR4 2014–2017
Dichloroacetic Acid
1.87 µg/L
No EPA limit set
worst single sample: 2 µg/L
6/9 SYR4 2012–2019
Fluoride
282.5 µg/L 7.1%
of the EPA limit 4000 µg/L
worst single sample: 290 µg/L
6/6 SYR4 2012–2018
Total Haloacetic Acids (HAA5)
4.5 µg/L 7.5%
of the EPA limit 60 µg/L
worst single sample: 5 µg/L
6/9 SYR4 2012–2019
Bromoform
4.48 µg/L
No EPA limit set
worst single sample: 5 µg/L
5/12 SYR4 2012–2019
Trichloroacetic Acid
2.89 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
4/9 SYR4 2012–2019
Arsenic
2 µg/L 20%
of the EPA limit 10 µg/L
3/3 SYR4 2012–2018
Barium
168.9 µg/L 8.4%
of the EPA limit 2000 µg/L
worst single sample: 170 µg/L
3/3 SYR4 2012–2018
Combined Radium (-226 And -228)
3.93 pCi/L 79%
of the EPA limit 5 pCi/L
worst single sample: 4 pCi/L
3/3 SYR4 2012–2018
35 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneDibromoacetic AcidEthylene DibromideEthylbenzeneMercuryMonobromoacetic AcidMonochloroacetic AcidNitrate-NitriteSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SMITH, BONNIE
Phone
973-948-5144

Frequently asked questions about Culver Lake Water Company

Is Culver Lake Water Company tap water safe to drink?

EPA monitoring detected 15 contaminants in Culver Lake Water Company's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Culver Lake Water Company's water?

EPA monitoring detected Lead, Copper, Chloroform, TTHM, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Culver Lake Water Company serve?

Culver Lake Water Company reports serving 40 people in New Jersey, per its EPA record.

Has Culver Lake Water Company had any water quality violations?

The EPA has 255 violations on file for Culver Lake Water Company, of which 6 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.