← New Jersey

Tap water quality report

Bancroft Neuro Health Center

EPA monitoring tested this supplier for 52 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

52
contaminants tested
18
detected
142
people served
10
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Salem

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

10
health-based violations
57
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2008-07-01 → 2008-07-31
MCL Health-based Resolved 2008-07-01 → 2008-07-31
MCL Health-based Resolved 2008-07-01 → 2008-07-31
MCL Health-based Resolved 2008-07-01 → 2008-07-31
MCL Health-based Resolved 2008-07-01 → 2008-07-31
MCL Health-based Resolved 2008-06-01 → 2008-06-30
MCL Health-based Resolved 2008-06-01 → 2008-06-30
MCL Health-based Resolved 2008-06-01 → 2008-06-30
MCL Health-based Resolved 2008-06-01 → 2008-06-30
MCL Health-based Resolved 2008-06-01 → 2008-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
764.4 µg/L 59%
of the EPA limit 1300 µg/L
worst single sample: 904 µg/L
65/66 SYR4 2012–2019
Lead
5.09 µg/L 34%
of the EPA limit 15 µg/L
worst single sample: 32.8 µg/L
59/63 SYR4 2012–2019
Chloroform
12.825 µg/L
No EPA limit set
worst single sample: 21.9 µg/L
26/26 SYR4 2012–2019
Bromodichloromethane
2.805 µg/L
No EPA limit set
worst single sample: 4.49 µg/L
23/26 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
21/21 LCR 2025
Dibromochloromethane
1.2 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
17/26 SYR4 2012–2019
Dichloroacetic Acid
6.7015 µg/L
No EPA limit set
worst single sample: 8.19 µg/L
14/14 SYR4 2012–2019
TTHM
12.805 µg/L 16%
of the EPA limit 80 µg/L
worst single sample: 14.3 µg/L
14/14 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
11.876 µg/L 20%
of the EPA limit 60 µg/L
worst single sample: 12.76 µg/L
14/14 SYR4 2012–2019
Trichloroacetic Acid
4.966 µg/L
No EPA limit set
worst single sample: 5.45 µg/L
12/14 SYR4 2012–2019
Xylenes, Total
4.7065 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 6.89 µg/L
12/15 SYR4 2012–2019
Ethylbenzene
1.1415 µg/L 0.2%
of the EPA limit 700 µg/L
worst single sample: 1.46 µg/L
8/15 SYR4 2012–2019
Barium
65.31 µg/L 3.3%
of the EPA limit 2000 µg/L
worst single sample: 65.9 µg/L
3/3 SYR4 2012–2018
Toluene
0.1520 µg/L 0%
of the EPA limit 1000 µg/L
worst single sample: 0.1600 µg/L
3/15 SYR4 2012–2019
Chromium
0.9902 µg/L 1%
of the EPA limit 100 µg/L
worst single sample: 1 µg/L
2/3 SYR4 2012–2018
Arsenic
0.2200 µg/L 2.2%
of the EPA limit 10 µg/L
1/3 SYR4 2012–2018
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
1/1 SYR4 2014
Selenium
0.4300 µg/L 0.9%
of the EPA limit 50 µg/L
1/3 SYR4 2012–2018
34 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalBenzeneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbon TetrachlorideDichloromethaneDibromoacetic AcidEthylene DibromideFluorideMercuryMonobromoacetic AcidMonochloroacetic AcidNitrateNitrate-NitriteNitriteStyreneTetrachloroethyleneThallium, TotalTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HITZEL, STEVEN

Frequently asked questions about Bancroft Neuro Health Center

Is Bancroft Neuro Health Center tap water safe to drink?

EPA monitoring detected 18 contaminants in Bancroft Neuro Health Center's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Bancroft Neuro Health Center's water?

EPA monitoring detected Copper, Lead, Chloroform, Bromodichloromethane, Lead, and others. The full list with the level and data source for each is above.

How many people does Bancroft Neuro Health Center serve?

Bancroft Neuro Health Center reports serving 142 people in New Jersey, per its EPA record.

Has Bancroft Neuro Health Center had any water quality violations?

The EPA has 57 violations on file for Bancroft Neuro Health Center, of which 10 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.