← New Jersey

Tap water quality report

Auburn Village Water Sup

EPA monitoring tested this supplier for 71 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

71
contaminants tested
19
detected
200
people served
5
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Salem

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
42
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2013-09-01 → 2013-09-30
MCL Health-based Resolved 2013-09-01 → 2013-09-30
MCL Health-based Resolved 2013-09-01 → 2013-09-30
MCL Health-based Archived 1996-06-01 → 1996-06-30
MCL Health-based Archived 1996-06-01 → 1996-06-30
Other Monitoring Resolved 2024-10-01
Other Monitoring Resolved 2024-10-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0069 mg/L 46%
of the EPA limit 0.0150 mg/L
16/16 LCR 2023
Chloroform
11.9 µg/L
No EPA limit set
worst single sample: 14 µg/L
15/17 SYR4 2012–2019
Copper
1128.45 µg/L 87%
of the EPA limit 1300 µg/L
worst single sample: 1900 µg/L
14/15 SYR4 2012–2018
Bromodichloromethane
2.4 µg/L
No EPA limit set
12/17 SYR4 2012–2019
TTHM
15.35 µg/L 19%
of the EPA limit 80 µg/L
worst single sample: 17 µg/L
12/13 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
6.8 µg/L 11%
of the EPA limit 60 µg/L
worst single sample: 7.4 µg/L
11/13 SYR4 2012–2019
Nitrate
1270 µg/L 13%
of the EPA limit 10000 µg/L
10/16 SYR4 2012–2019
Trichloroacetic Acid
3.23 µg/L
No EPA limit set
worst single sample: 3.5 µg/L
10/13 SYR4 2012–2019
Dichloroacetic Acid
3.585 µg/L
No EPA limit set
worst single sample: 3.9 µg/L
8/13 SYR4 2012–2019
Lead
17.68 µg/L 118%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 20.2 µg/L
8/10 SYR4 2014–2017
Dibromochloromethane
0.4700 µg/L
No EPA limit set
worst single sample: 0.5000 µg/L
7/16 SYR4 2012–2019
Fluoride
328.1 µg/L 8.2%
of the EPA limit 4000 µg/L
worst single sample: 380 µg/L
7/9 SYR4 2012–2018
Barium
34.62 µg/L 1.7%
of the EPA limit 2000 µg/L
worst single sample: 35.1 µg/L
5/5 SYR4 2012–2018
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
2/2 SYR4 2012–2015
Monochloroacetic Acid
0.4740 µg/L
No EPA limit set
worst single sample: 0.4800 µg/L
2/13 SYR4 2012–2019
Selenium
0.2235 µg/L 0.4%
of the EPA limit 50 µg/L
worst single sample: 0.2300 µg/L
2/5 SYR4 2012–2018
Arsenic
0.1500 µg/L 1.5%
of the EPA limit 10 µg/L
1/5 SYR4 2012–2018
Chromium
2.4 µg/L 2.4%
of the EPA limit 100 µg/L
1/5 SYR4 2012–2018
Mercury
0.0350 µg/L 1.8%
of the EPA limit 2 µg/L
1/5 SYR4 2012–2018
52 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideDichloromethaneDalaponDibromoacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorMonobromoacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
TAYLOR, MELINDA
Phone
856-299-0780

Frequently asked questions about Auburn Village Water Sup

Is Auburn Village Water Sup tap water safe to drink?

EPA monitoring detected 19 contaminants in Auburn Village Water Sup's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Auburn Village Water Sup's water?

EPA monitoring detected Lead, Chloroform, Copper, Bromodichloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Auburn Village Water Sup serve?

Auburn Village Water Sup reports serving 200 people in New Jersey, per its EPA record.

Has Auburn Village Water Sup had any water quality violations?

The EPA has 42 violations on file for Auburn Village Water Sup, of which 5 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.