Tap water quality report

Passaic Valley W C High Crest

EPA monitoring tested this supplier for 14 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
12
detected
1,132
people served
32
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Passaic

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

32
health-based violations
76
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-01-01 → 2019-03-31
MCL Health-based Resolved 2019-01-01 → 2019-03-31
MCL Health-based Resolved 2019-01-01 → 2019-03-31
MCL Health-based Resolved 2019-01-01 → 2019-03-31
MCL Health-based Resolved 2019-01-01 → 2019-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
14.1 µg/L
No EPA limit set
worst single sample: 14.6 µg/L
46/46 SYR4 2012–2019
Chloroform
86.7 µg/L
No EPA limit set
worst single sample: 95.7 µg/L
46/46 SYR4 2012–2019
Dibromochloromethane
2.2075 µg/L
No EPA limit set
worst single sample: 2.53 µg/L
46/46 SYR4 2012–2019
Dichloroacetic Acid
24.25 µg/L
No EPA limit set
worst single sample: 26.2 µg/L
46/46 SYR4 2012–2019
TTHM
101.8 µg/L 127%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 112.3 µg/L
46/46 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
51.95 µg/L 87%
of the EPA limit 60 µg/L
worst single sample: 59.5 µg/L
46/46 SYR4 2012–2019
Trichloroacetic Acid
26.875 µg/L
No EPA limit set
worst single sample: 29.7 µg/L
46/46 SYR4 2012–2019
Monochloroacetic Acid
3.616 µg/L
No EPA limit set
worst single sample: 4.33 µg/L
45/46 SYR4 2012–2019
Copper
246.36 µg/L 19%
of the EPA limit 1300 µg/L
worst single sample: 269.8 µg/L
29/31 SYR4 2012–2018
Lead
20.4965 µg/L 137%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 31.72 µg/L
22/31 SYR4 2012–2018
Lead
0.00062 mg/L 4.1%
of the EPA limit 0.0150 mg/L
14/14 LCR 2024
Monobromoacetic Acid
1.1915 µg/L
No EPA limit set
worst single sample: 1.2 µg/L
2/46 SYR4 2012–2019
2 contaminants tested, none detected
BromoformDibromoacetic Acid

Utility contact

Contact
MUELLER, JAMES
Phone
973-340-4307

Frequently asked questions about Passaic Valley W C High Crest

Is Passaic Valley W C High Crest tap water safe to drink?

EPA monitoring detected 12 contaminants in Passaic Valley W C High Crest's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Passaic Valley W C High Crest's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Passaic Valley W C High Crest serve?

Passaic Valley W C High Crest reports serving 1,132 people in New Jersey, per its EPA record.

Has Passaic Valley W C High Crest had any water quality violations?

The EPA has 76 violations on file for Passaic Valley W C High Crest, of which 32 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.