← New Jersey

Tap water quality report

Lacey Twp Mua

EPA monitoring tested this supplier for 81 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

81
contaminants tested
25
detected
29,000
people served
9
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Ocean

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

9
health-based violations
189
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2023-07-01 → 2023-12-31
TT Health-based Resolved 2023-07-01 → 2023-12-31
TT Health-based Resolved 2023-07-01 → 2023-12-31
TT Health-based Resolved 2023-07-01 → 2023-12-31
TT Health-based Resolved 2023-07-01 → 2023-12-31
MCL Health-based Resolved 2015-04-01 → 2015-04-30
MCL Health-based Resolved 2015-04-01 → 2015-04-30
MCL Health-based Resolved 2015-04-01 → 2015-04-30
MCL Health-based Resolved 2015-04-01 → 2015-04-30
MR Monitoring Resolved 2025-01-01 → 2025-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Total Haloacetic Acids (HAA5)
14.23 µg/L 24%
of the EPA limit 60 µg/L
worst single sample: 29.4 µg/L
119/121 SYR4 2012–2019
TTHM
7.776 µg/L 9.7%
of the EPA limit 80 µg/L
worst single sample: 12.5 µg/L
105/120 SYR4 2012–2019
Dichloroacetic Acid
2.585 µg/L
No EPA limit set
worst single sample: 5.31 µg/L
96/121 SYR4 2012–2019
Dibromochloromethane
2.455 µg/L
No EPA limit set
worst single sample: 3.67 µg/L
95/120 SYR4 2012–2019
Chloroform
2.85 µg/L
No EPA limit set
worst single sample: 3.8 µg/L
94/120 SYR4 2012–2019
Bromodichloromethane
2.666 µg/L
No EPA limit set
worst single sample: 3.83 µg/L
90/120 SYR4 2012–2019
Monochloroacetic Acid
12.24 µg/L
No EPA limit set
worst single sample: 20.6 µg/L
87/121 SYR4 2012–2019
Copper
193.75 µg/L 15%
of the EPA limit 1300 µg/L
worst single sample: 288 µg/L
50/101 SYR4 2012–2018
Bromoform
1.0135 µg/L
No EPA limit set
worst single sample: 1.23 µg/L
38/120 SYR4 2012–2019
Dibromoacetic Acid
2.2755 µg/L
No EPA limit set
worst single sample: 2.39 µg/L
28/121 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
18/18 LCR 2025
Monobromoacetic Acid
5.588 µg/L
No EPA limit set
worst single sample: 5.69 µg/L
18/121 SYR4 2012–2019
Lead
20.8635 µg/L 139%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 30.1 µg/L
8/101 SYR4 2012–2018
Ethylbenzene
4.9125 µg/L 0.7%
of the EPA limit 700 µg/L
worst single sample: 4.96 µg/L
6/64 SYR4 2012–2019
Xylenes, Total
20.515 µg/L 0.2%
of the EPA limit 10000 µg/L
worst single sample: 22.15 µg/L
6/63 SYR4 2012–2019
Dichloromethane
0.2640 µg/L 5.3%
of the EPA limit 5 µg/L
worst single sample: 0.2900 µg/L
5/64 SYR4 2012–2019
Barium
44.84 µg/L 2.2%
of the EPA limit 2000 µg/L
worst single sample: 46.1 µg/L
4/4 SYR4 2014–2017
Trichloroacetic Acid
1.25 µg/L
No EPA limit set
worst single sample: 1.27 µg/L
3/121 SYR4 2012–2019
Nitrate
27 µg/L 0.3%
of the EPA limit 10000 µg/L
2/30 SYR4 2012–2019
Styrene
0.5725 µg/L 0.6%
of the EPA limit 100 µg/L
worst single sample: 0.5900 µg/L
2/64 SYR4 2012–2019
Benzene
0.1100 µg/L 2.2%
of the EPA limit 5 µg/L
1/64 SYR4 2012–2019
Combined Radium (-226 And -228)
1.32 pCi/L 26%
of the EPA limit 5 pCi/L
1/4 SYR4 2017
Combined Uranium
1.23 µg/L 4.1%
of the EPA limit 30 µg/L
1/4 SYR4 2017
Thallium, Total
0.4670 µg/L 23%
of the EPA limit 2 µg/L
1/4 SYR4 2014–2017
Toluene
0.4100 µg/L 0%
of the EPA limit 1000 µg/L
1/64 SYR4 2012–2019
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumFluorideGross Alpha, Excl. Radon And UHfpo-DaMercuryNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaSeleniumTetrachloroethyleneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
VERGE, DEREK
Phone
609-694-8295

Frequently asked questions about Lacey Twp Mua

Is Lacey Twp Mua tap water safe to drink?

EPA monitoring detected 25 contaminants in Lacey Twp Mua's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lacey Twp Mua's water?

EPA monitoring detected Total Haloacetic Acids (HAA5), TTHM, Dichloroacetic Acid, Dibromochloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Lacey Twp Mua serve?

Lacey Twp Mua reports serving 29,000 people in New Jersey, per its EPA record.

Has Lacey Twp Mua had any water quality violations?

The EPA has 189 violations on file for Lacey Twp Mua, of which 9 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.