← New Jersey

Tap water quality report

Nj American Water - Coastal North

EPA monitoring tested this supplier for 100 contaminants and detected 31. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

100
contaminants tested
31
detected
377,613
people served
4
health-based violations
Water source
Surface water
Ownership
Private
Counties served
Monmouth, Ocean

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
70
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2019-09-01 → 2019-09-30
TT Health-based Resolved 2019-09-01 → 2019-09-30
TT Health-based Resolved 2019-09-01 → 2019-09-30
TT Health-based Resolved 2019-09-01 → 2019-09-30
MR Monitoring Archived 2023-01-01 → 2023-06-30
MR Monitoring Archived 2023-01-01 → 2023-06-30
MR Monitoring Resolved 2020-05-01 → 2020-05-31
MR Monitoring Resolved 2020-05-01 → 2020-05-31
MR Monitoring Resolved 2020-05-01 → 2020-05-31
MR Monitoring Resolved 2015-06-01 → 2015-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFOA 0.0075 µg/L 18/38 2024
Pfhxa 0.0046 µg/L 12/38 2024
Pfpea 0.0048 µg/L 10/38 2024
PFBS 0.0092 µg/L 2/38 2024
6:2 Fts 0.0068 µg/L 1/38 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
19.36 µg/L
No EPA limit set
worst single sample: 23.4 µg/L
405/405 SYR4 2012–2019
Chloroform
68.96 µg/L
No EPA limit set
worst single sample: 89.3 µg/L
405/405 SYR4 2012–2019
TTHM
89.56 µg/L 112%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 114.7 µg/L
405/405 SYR4 2012–2019
Dibromochloromethane
5.4 µg/L
No EPA limit set
worst single sample: 7.4 µg/L
401/405 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
38.195 µg/L 64%
of the EPA limit 60 µg/L
worst single sample: 75 µg/L
398/405 SYR4 2012–2019
Dichloroacetic Acid
16.575 µg/L
No EPA limit set
worst single sample: 34 µg/L
396/405 SYR4 2012–2019
Trichloroacetic Acid
23.15 µg/L
No EPA limit set
worst single sample: 42.3 µg/L
396/405 SYR4 2012–2019
Copper
190.15 µg/L 15%
of the EPA limit 1300 µg/L
worst single sample: 847 µg/L
338/448 SYR4 2012–2019
Chlorite
450 µg/L 45%
of the EPA limit 1000 µg/L
worst single sample: 570 µg/L
263/279 SYR4 2012–2019
Monobromoacetic Acid
6.135 µg/L
No EPA limit set
worst single sample: 7 µg/L
174/405 SYR4 2012–2019
Lead
19.65 µg/L 131%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 79 µg/L
128/400 SYR4 2014–2019
Nitrate
1520 µg/L 15%
of the EPA limit 10000 µg/L
worst single sample: 1680 µg/L
92/226 SYR4 2012–2019
Fluoride
750 µg/L 19%
of the EPA limit 4000 µg/L
worst single sample: 870 µg/L
49/96 SYR4 2012–2019
Dibromoacetic Acid
1.665 µg/L
No EPA limit set
worst single sample: 1.9 µg/L
48/405 SYR4 2012–2019
Nitrate-Nitrite
1482.5 µg/L 15%
of the EPA limit 10000 µg/L
worst single sample: 1680 µg/L
46/113 SYR4 2012–2019
Combined Radium (-226 And -228)
3.76 pCi/L 75%
of the EPA limit 5 pCi/L
worst single sample: 4.18 pCi/L
35/74 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
24/24 LCR 2026
Monochloroacetic Acid
3.46 µg/L
No EPA limit set
worst single sample: 3.8 µg/L
18/405 SYR4 2012–2019
Bromoform
0.6400 µg/L
No EPA limit set
worst single sample: 0.7000 µg/L
13/405 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
0.0600 µg/L 1%
of the EPA limit 6 µg/L
4/6 SYR4 2012–2018
Xylenes, Total
0.6900 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 0.7000 µg/L
3/119 SYR4 2012–2019
Carbon Tetrachloride
0.6950 µg/L 14%
of the EPA limit 5 µg/L
worst single sample: 0.7000 µg/L
2/119 SYR4 2012–2019
Atrazine
0.0600 µg/L 2%
of the EPA limit 3 µg/L
1/6 SYR4 2012–2018
Cyanide
6 µg/L 3%
of the EPA limit 200 µg/L
1/48 SYR4 2012–2019
Styrene
0.5000 µg/L 0.5%
of the EPA limit 100 µg/L
1/119 SYR4 2012–2019
Lithium
10.2 µg/L
No EPA limit set
1/38 UCMR-5 2024
69 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromateChlorobenzeneCadmiumChromiumDichloromethaneDi(2-ethylhexyl) AdipateDinosebEndrinEthylbenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitritePfbaPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
JACOBUS, BRIAN
Phone
732-547-8783

Frequently asked questions about Nj American Water - Coastal North

Is Nj American Water - Coastal North tap water safe to drink?

EPA monitoring detected 31 contaminants in Nj American Water - Coastal North's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Nj American Water - Coastal North's water?

EPA monitoring detected Bromodichloromethane, Chloroform, TTHM, Dibromochloromethane, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Nj American Water - Coastal North serve?

Nj American Water - Coastal North reports serving 377,613 people in New Jersey, per its EPA record.

Has Nj American Water - Coastal North had any water quality violations?

The EPA has 70 violations on file for Nj American Water - Coastal North, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.