← New Jersey

Tap water quality report

Gateway Nra Sandy Hook

EPA monitoring tested this supplier for 51 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

51
contaminants tested
18
detected
500
people served
27
health-based violations
Water source
Ground water
Ownership
Federal government
Counties served
Monmouth

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

27
health-based violations
212
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2022-01-01 → 2022-06-30
TT Health-based Resolved 2022-01-01 → 2022-06-30
TT Health-based Resolved 2022-01-01 → 2022-06-30
TT Health-based Resolved 2022-01-01 → 2022-06-30
TT Health-based Resolved 2021-07-01 → 2021-12-31
TT Health-based Resolved 2021-07-01 → 2021-12-31
TT Health-based Resolved 2021-07-01 → 2021-12-31
TT Health-based Resolved 2021-07-01 → 2021-12-31
MCL Health-based Resolved 1997-09-01 → 1997-09-30
MCL Health-based Resolved 1997-09-01 → 1997-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0022 mg/L 15%
of the EPA limit 0.0150 mg/L
23/23 LCR 2026
Copper
123.6 µg/L 9.5%
of the EPA limit 1300 µg/L
worst single sample: 158 µg/L
17/18 SYR4 2013–2019
Dibromochloromethane
3.26 µg/L
No EPA limit set
worst single sample: 3.5 µg/L
17/18 SYR4 2012–2019
Bromodichloromethane
3.375 µg/L
No EPA limit set
worst single sample: 3.9 µg/L
16/18 SYR4 2012–2019
TTHM
11.09 µg/L 14%
of the EPA limit 80 µg/L
worst single sample: 12 µg/L
15/16 SYR4 2012–2019
Chloroform
3.025 µg/L
No EPA limit set
worst single sample: 4 µg/L
14/18 SYR4 2012–2019
Lead
11.7 µg/L 78%
of the EPA limit 15 µg/L
worst single sample: 14.4 µg/L
11/15 SYR4 2013–2019
Bromoform
1.36 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
8/18 SYR4 2012–2019
Barium
48.24 µg/L 2.4%
of the EPA limit 2000 µg/L
worst single sample: 48.9 µg/L
3/3 SYR4 2013–2018
Dichloroacetic Acid
0.9670 µg/L
No EPA limit set
worst single sample: 1 µg/L
3/16 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
1 µg/L 1.7%
of the EPA limit 60 µg/L
3/16 SYR4 2012–2019
Combined Radium (-226 And -228)
2.507 pCi/L 50%
of the EPA limit 5 pCi/L
worst single sample: 2.56 pCi/L
2/2 SYR4 2013–2018
Fluoride
59.265 µg/L 1.5%
of the EPA limit 4000 µg/L
worst single sample: 59.8 µg/L
2/6 SYR4 2013–2018
Mercury
0.0329 µg/L 1.6%
of the EPA limit 2 µg/L
worst single sample: 0.0330 µg/L
2/3 SYR4 2013–2018
Selenium
1.064 µg/L 2.1%
of the EPA limit 50 µg/L
worst single sample: 1.1 µg/L
2/3 SYR4 2013–2018
Arsenic
0.1700 µg/L 1.7%
of the EPA limit 10 µg/L
1/3 SYR4 2013–2018
Dibromoacetic Acid
0.3000 µg/L
No EPA limit set
1/16 SYR4 2012–2019
P-Dichlorobenzene
0.2700 µg/L 0.4%
of the EPA limit 75 µg/L
1/3 SYR4 2013–2018
33 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalAsbestosBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneEthylene DibromideEthylbenzeneMonobromoacetic AcidMonochloroacetic AcidNitrateStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MCDERMOTT, LISA
Phone
732-962-8996

Frequently asked questions about Gateway Nra Sandy Hook

Is Gateway Nra Sandy Hook tap water safe to drink?

EPA monitoring detected 18 contaminants in Gateway Nra Sandy Hook's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Gateway Nra Sandy Hook's water?

EPA monitoring detected Lead, Copper, Dibromochloromethane, Bromodichloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Gateway Nra Sandy Hook serve?

Gateway Nra Sandy Hook reports serving 500 people in New Jersey, per its EPA record.

Has Gateway Nra Sandy Hook had any water quality violations?

The EPA has 212 violations on file for Gateway Nra Sandy Hook, of which 27 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.