← New Jersey

Tap water quality report

Perth Amboy Water Department

EPA monitoring tested this supplier for 85 contaminants and detected 32. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

85
contaminants tested
32
detected
52,328
people served
26
health-based violations
Water source
Ground water under surface influence
Ownership
Local government
Counties served
Middlesex

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

26
health-based violations
189
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Resolved 2019-07-01 → 2019-09-30
MCL Health-based Resolved 2019-07-01 → 2019-09-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Hfpo-Da 0.0140 µg/L 4/4 2025
Pfhxa 0.0044 µg/L 4/4 2025
PFOA 0.0190 µg/L 4/4 2025
Pfpea 0.0053 µg/L 4/4 2025
PFOS 0.0049 µg/L 3/4 2025
Pfba 0.0051 µg/L 2/4 2025
Pfhpa 0.0034 µg/L 2/4 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
29.6 µg/L
No EPA limit set
worst single sample: 32.5 µg/L
158/158 SYR4 2012–2019
Chloroform
61.63 µg/L
No EPA limit set
worst single sample: 84.6 µg/L
158/158 SYR4 2012–2019
Dibromochloromethane
21.59 µg/L
No EPA limit set
worst single sample: 30 µg/L
158/158 SYR4 2012–2019
Bromoform
10.115 µg/L
No EPA limit set
worst single sample: 13.8 µg/L
140/158 SYR4 2012–2019
Dichloroacetic Acid
19.86 µg/L
No EPA limit set
worst single sample: 33.4 µg/L
135/139 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
53.53 µg/L 89%
of the EPA limit 60 µg/L
worst single sample: 86 µg/L
135/139 SYR4 2012–2019
Trichloroacetic Acid
31.59 µg/L
No EPA limit set
worst single sample: 49 µg/L
132/139 SYR4 2012–2019
TTHM
102.9 µg/L 129%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 125 µg/L
131/131 SYR4 2012–2019
Dibromoacetic Acid
5.937 µg/L
No EPA limit set
worst single sample: 7.88 µg/L
114/139 SYR4 2012–2019
Copper
409.9 µg/L 32%
of the EPA limit 1300 µg/L
worst single sample: 4290 µg/L
70/291 SYR4 2012–2019
Lead
135.3 µg/L 902%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 375 µg/L
60/286 SYR4 2012–2019
Monobromoacetic Acid
6.156 µg/L
No EPA limit set
worst single sample: 6.33 µg/L
45/139 SYR4 2012–2019
Monochloroacetic Acid
21.32 µg/L
No EPA limit set
worst single sample: 23.7 µg/L
27/139 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
26/26 LCR 2025
Combined Radium (-226 And -228)
4.36 pCi/L 87%
of the EPA limit 5 pCi/L
worst single sample: 4.42 pCi/L
11/11 SYR4 2014–2019
Gross Alpha, Excl. Radon And U
17.6 pCi/L 117%
of the EPA limit, at the 95th percentile of samples — 15 pCi/L
worst single sample: 18.2 pCi/L
11/11 SYR4 2014–2019
Fluoride
632.55 µg/L 16%
of the EPA limit 4000 µg/L
worst single sample: 651 µg/L
10/12 SYR4 2012–2019
Barium
203.4 µg/L 10%
of the EPA limit 2000 µg/L
worst single sample: 243 µg/L
9/12 SYR4 2012–2019
Arsenic
0.9173 µg/L 9.2%
of the EPA limit 10 µg/L
worst single sample: 1 µg/L
4/12 SYR4 2012–2019
Selenium
3.458 µg/L 6.9%
of the EPA limit 50 µg/L
worst single sample: 3.46 µg/L
3/12 SYR4 2012–2019
Chromium
1.2975 µg/L 1.3%
of the EPA limit 100 µg/L
worst single sample: 1.34 µg/L
2/12 SYR4 2012–2019
Nitrate
1430 µg/L 14%
of the EPA limit 10000 µg/L
2/20 SYR4 2013–2019
Thallium, Total
0.6203 µg/L 31%
of the EPA limit 2 µg/L
worst single sample: 0.6360 µg/L
2/12 SYR4 2012–2019
Beryllium, Total
0.0440 µg/L 1.1%
of the EPA limit 4 µg/L
1/12 SYR4 2012–2019
Mercury
0.0420 µg/L 2.1%
of the EPA limit 2 µg/L
1/13 SYR4 2012–2019
53 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosBenzeneChlorobenzeneCyanideCadmiumCarbon TetrachlorideCombined UraniumDichloromethaneEthylene DibromideEthylbenzeneNetfosaaNfdhaNmefosaaNitrate-NitriteNitritePFBSPfdaPfdoaPfeesaPfhpsPFHXSPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaStyreneTetrachloroethyleneTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FULLAGAR, ROBERT
Phone
732-638-7537

Frequently asked questions about Perth Amboy Water Department

Is Perth Amboy Water Department tap water safe to drink?

EPA monitoring detected 32 contaminants in Perth Amboy Water Department's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Perth Amboy Water Department's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, Bromoform, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Perth Amboy Water Department serve?

Perth Amboy Water Department reports serving 52,328 people in New Jersey, per its EPA record.

Has Perth Amboy Water Department had any water quality violations?

The EPA has 189 violations on file for Perth Amboy Water Department, of which 26 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.