← New Jersey

Tap water quality report

Lawrenceville School

EPA monitoring tested this supplier for 68 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

68
contaminants tested
25
detected
1,200
people served
1
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Mercer

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

1
health-based violations
157
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2014-01-01
RPT Monitoring Unaddressed 2025-02-11
MON Monitoring Archived 2025-01-01 → 2025-01-31
MON Monitoring Archived 2025-01-01 → 2025-01-31
MON Monitoring Archived 2025-01-01 → 2025-01-31
MR Monitoring Archived 2025-01-01 → 2025-03-31
MR Monitoring Archived 2025-01-01 → 2025-03-31
MR Monitoring Archived 2025-01-01 → 2025-03-31
MR Monitoring Resolved 2016-09-15
MR Monitoring Resolved 2016-09-15

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
1514 µg/L 116%
of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 10700 µg/L
104/112 SYR4 2012–2019
Lead
68.1 µg/L 454%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 958 µg/L
93/103 SYR4 2012–2019
Nitrate
4102.5 µg/L 41%
of the EPA limit 10000 µg/L
worst single sample: 4200 µg/L
34/34 SYR4 2012–2018
Bromoform
16.2 µg/L
No EPA limit set
worst single sample: 17.7 µg/L
26/29 SYR4 2012–2019
Dibromochloromethane
13.25 µg/L
No EPA limit set
worst single sample: 14.7 µg/L
26/29 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
26/26 LCR 2025
Bromodichloromethane
11.43 µg/L
No EPA limit set
worst single sample: 14 µg/L
24/29 SYR4 2012–2019
Chloroform
52.2 µg/L
No EPA limit set
worst single sample: 56 µg/L
20/29 SYR4 2012–2019
TTHM
67.05 µg/L 84%
of the EPA limit 80 µg/L
worst single sample: 73 µg/L
18/18 SYR4 2012–2019
Barium
510 µg/L 26%
of the EPA limit 2000 µg/L
worst single sample: 590 µg/L
6/6 SYR4 2012–2018
Total Haloacetic Acids (HAA5)
16.9175 µg/L 28%
of the EPA limit 60 µg/L
worst single sample: 19.9 µg/L
6/18 SYR4 2012–2019
Xylenes, Total
1.085 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 1.09 µg/L
6/12 SYR4 2012–2018
Arsenic
0.8940 µg/L 8.9%
of the EPA limit 10 µg/L
worst single sample: 0.9300 µg/L
5/6 SYR4 2012–2018
Selenium
2.56 µg/L 5.1%
of the EPA limit 50 µg/L
worst single sample: 2.6 µg/L
5/6 SYR4 2012–2018
Dibromoacetic Acid
2.273 µg/L
No EPA limit set
worst single sample: 2.39 µg/L
4/18 SYR4 2012–2019
Chromium
2.02 µg/L 2%
of the EPA limit 100 µg/L
worst single sample: 2.1 µg/L
3/6 SYR4 2012–2018
Combined Radium (-226 And -228)
2.418 pCi/L 48%
of the EPA limit 5 pCi/L
worst single sample: 2.52 pCi/L
3/4 SYR4 2012–2018
Monochloroacetic Acid
15.9785 µg/L
No EPA limit set
worst single sample: 16.4 µg/L
2/18 SYR4 2012–2019
Thallium, Total
0.0590 µg/L 2.9%
of the EPA limit 2 µg/L
worst single sample: 0.0600 µg/L
2/6 SYR4 2012–2018
Antimony, Total
0.0900 µg/L 1.5%
of the EPA limit 6 µg/L
1/6 SYR4 2012–2018
Beryllium, Total
0.0600 µg/L 1.5%
of the EPA limit 4 µg/L
1/6 SYR4 2012–2018
Ethylbenzene
0.1500 µg/L 0%
of the EPA limit 700 µg/L
1/12 SYR4 2012–2018
Monobromoacetic Acid
1.08 µg/L
No EPA limit set
1/18 SYR4 2012–2019
Nitrate-Nitrite
3080 µg/L 31%
of the EPA limit 10000 µg/L
1/1 SYR4 2019
Trichloroacetic Acid
1.07 µg/L
No EPA limit set
1/18 SYR4 2012–2019
43 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAtrazineBhc-GammaBenzeneBenzo(A)PyreneChlorobenzeneCyanideCadmiumCarbon TetrachlorideDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebEthylene DibromideEndrinFluorideHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SMITH, ROBERT
Phone
609-895-2081

Frequently asked questions about Lawrenceville School

Is Lawrenceville School tap water safe to drink?

EPA monitoring detected 25 contaminants in Lawrenceville School's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lawrenceville School's water?

EPA monitoring detected Copper, Lead, Nitrate, Bromoform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Lawrenceville School serve?

Lawrenceville School reports serving 1,200 people in New Jersey, per its EPA record.

Has Lawrenceville School had any water quality violations?

The EPA has 157 violations on file for Lawrenceville School, of which 1 is health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.