← New Jersey

Tap water quality report

Harrison W Dept

EPA monitoring tested this supplier for 44 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
18
detected
14,425
people served
10
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Hudson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

10
health-based violations
43
violations on file
4
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2011-11-01 → 2011-11-30
MCL Health-based Resolved 2011-11-01 → 2011-11-30
MCL Health-based Resolved 2011-11-01 → 2011-11-30
MCL Health-based Resolved 2011-11-01 → 2011-11-30
MCL Health-based Resolved 2001-10-01 → 2001-10-31
MCL Health-based Resolved 2001-10-01 → 2001-10-31
MCL Health-based Resolved 2001-10-01 → 2001-10-31
MCL Health-based Resolved 2000-08-01 → 2000-08-31
MCL Health-based Resolved 2000-08-01 → 2000-08-31
MCL Health-based Resolved 2000-08-01 → 2000-08-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFOA 0.0088 µg/L 4/4 2024
Pfhxa 0.0072 µg/L 2/4 2024
PFOS 0.0062 µg/L 2/4 2024
Pfpea 0.0086 µg/L 2/4 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
18.66 µg/L
No EPA limit set
worst single sample: 22.5 µg/L
125/125 SYR4 2012–2019
Chloroform
52.4 µg/L
No EPA limit set
worst single sample: 70.8 µg/L
125/125 SYR4 2012–2019
Dibromochloromethane
9.166 µg/L
No EPA limit set
worst single sample: 14.1 µg/L
125/125 SYR4 2012–2019
Dichloroacetic Acid
17.98 µg/L
No EPA limit set
worst single sample: 22 µg/L
125/125 SYR4 2012–2019
TTHM
76.08 µg/L 95%
of the EPA limit 80 µg/L
worst single sample: 95.9 µg/L
125/125 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
35.364 µg/L 59%
of the EPA limit 60 µg/L
worst single sample: 46 µg/L
125/125 SYR4 2012–2019
Trichloroacetic Acid
17.7 µg/L
No EPA limit set
worst single sample: 19.3 µg/L
125/125 SYR4 2012–2019
Monochloroacetic Acid
3.834 µg/L
No EPA limit set
worst single sample: 7.92 µg/L
107/125 SYR4 2012–2019
Copper
62.539 µg/L 4.8%
of the EPA limit 1300 µg/L
worst single sample: 122.1 µg/L
92/92 SYR4 2012–2018
Bromoform
1.83 µg/L
No EPA limit set
worst single sample: 1.97 µg/L
53/125 SYR4 2012–2019
Lead
7.3105 µg/L 49%
of the EPA limit 15 µg/L
worst single sample: 11.54 µg/L
48/92 SYR4 2012–2018
Dibromoacetic Acid
2.088 µg/L
No EPA limit set
worst single sample: 3.9 µg/L
47/125 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
22/22 LCR 2024
Monobromoacetic Acid
2.98 µg/L
No EPA limit set
worst single sample: 3.9 µg/L
9/125 SYR4 2012–2019
26 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaHfpo-DaNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
STARR, JOHN
Phone
973-268-2294

Frequently asked questions about Harrison W Dept

Is Harrison W Dept tap water safe to drink?

EPA monitoring detected 18 contaminants in Harrison W Dept's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Harrison W Dept's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Harrison W Dept serve?

Harrison W Dept reports serving 14,425 people in New Jersey, per its EPA record.

Has Harrison W Dept had any water quality violations?

The EPA has 43 violations on file for Harrison W Dept, of which 10 are health-based (a contaminant limit or required treatment was breached) and 4 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.