Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 1993-01-01 → 1993-12-31 |
| MCL | Health-based | Resolved | 1992-01-01 → 1992-12-31 |
| MCL | Health-based | Resolved | 1992-01-01 → 1992-12-31 |
| MCL | Health-based | Resolved | 1991-01-01 → 1991-06-30 |
| MCL | Health-based | Resolved | 1991-01-01 → 1991-06-30 |
| MCL | Health-based | Resolved | 1991-01-01 → 1991-06-30 |
| MCL | Health-based | Resolved | 1991-01-01 → 1991-12-31 |
| MCL | Health-based | Resolved | 1991-01-01 → 1991-12-31 |
| MCL | Health-based | Resolved | 1989-08-01 → 1989-10-31 |
| MCL | Health-based | Resolved | 1989-08-01 → 1989-10-31 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromoform | 16.21 µg/L No EPA limit set
worst single sample: 29.8 µg/L | 207/300 | SYR4 | 2012–2019 |
| Dibromochloromethane | 8.98 µg/L No EPA limit set
worst single sample: 13.9 µg/L | 193/300 | SYR4 | 2012–2019 |
| TTHM | 29.315 µg/L 37% of the EPA limit 80 µg/L
worst single sample: 48.6 µg/L | 132/142 | SYR4 | 2012–2019 |
| Bromodichloromethane | 4.108 µg/L No EPA limit set
worst single sample: 5.91 µg/L | 122/300 | SYR4 | 2012–2019 |
| Nitrate | 3893 µg/L 39% of the EPA limit 10000 µg/L
worst single sample: 4300 µg/L | 70/70 | SYR4 | 2012–2018 |
| Chloroform | 5.32 µg/L No EPA limit set
worst single sample: 5.89 µg/L | 44/300 | SYR4 | 2012–2019 |
| cis-1,2-Dichloroethylene | 1.363 µg/L 1.9% of the EPA limit 70 µg/L
worst single sample: 1.4 µg/L | 27/180 | SYR4 | 2012–2019 |
| Trichloroethylene | 1.488 µg/L 30% of the EPA limit 5 µg/L
worst single sample: 2 µg/L | 24/180 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 5.33 pCi/L 107% of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 5.6 pCi/L | 19/19 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 18/18 | LCR | 2024 |
| Copper | 947.25 µg/L 73% of the EPA limit 1300 µg/L
worst single sample: 1563 µg/L | 16/90 | SYR4 | 2012–2018 |
| Total Haloacetic Acids (HAA5) | 5.7 µg/L 9.5% of the EPA limit 60 µg/L
worst single sample: 6.3 µg/L | 11/138 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 3608.5 µg/L 36% of the EPA limit 10000 µg/L
worst single sample: 3640 µg/L | 10/10 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 2.7 µg/L No EPA limit set
worst single sample: 2.82 µg/L | 9/138 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 14.154 pCi/L 94% of the EPA limit 15 pCi/L
worst single sample: 14.55 pCi/L | 9/9 | SYR4 | 2012–2014 |
| Lead | 10.26 µg/L 68% of the EPA limit 15 µg/L
worst single sample: 11.3 µg/L | 9/90 | SYR4 | 2012–2018 |
| Lithium | 25.6 µg/L No EPA limit set | 9/13 | UCMR-5 | 2025 |
| 1,2-Dichloroethane | 0.6800 µg/L 14% of the EPA limit 5 µg/L
worst single sample: 0.7000 µg/L | 5/180 | SYR4 | 2012–2019 |
| Dichloromethane | 1.9 µg/L 38% of the EPA limit 5 µg/L
worst single sample: 2.1 µg/L | 5/180 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 3.482 µg/L No EPA limit set
worst single sample: 3.53 µg/L | 5/138 | SYR4 | 2012–2019 |
| Combined Uranium | 0.9476 µg/L 3.2% of the EPA limit 30 µg/L
worst single sample: 1.0132 µg/L | 3/9 | SYR4 | 2012–2014 |
| Dichloroacetic Acid | 1.301 µg/L No EPA limit set
worst single sample: 1.31 µg/L | 3/138 | SYR4 | 2012–2019 |
| Xylenes, Total | 1.07 µg/L 0% of the EPA limit 10000 µg/L
worst single sample: 1.1 µg/L | 2/180 | SYR4 | 2012–2019 |
| Di(2-ethylhexyl) Phthalate | 0.5900 µg/L 9.8% of the EPA limit 6 µg/L | 1/1 | SYR4 | 2018 |
71 contaminants tested, none detected
Utility contact
Frequently asked questions about Merchantville Pennsauken
Is Merchantville Pennsauken tap water safe to drink?
EPA monitoring detected 30 contaminants in Merchantville Pennsauken's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Merchantville Pennsauken's water?
EPA monitoring detected Bromoform, Dibromochloromethane, TTHM, Bromodichloromethane, Nitrate, and others. The full list with the level and data source for each is above.
How many people does Merchantville Pennsauken serve?
Merchantville Pennsauken reports serving 47,144 people in New Jersey, per its EPA record.
Has Merchantville Pennsauken had any water quality violations?
The EPA has 303 violations on file for Merchantville Pennsauken, of which 12 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.