Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2020-04-01 → 2020-06-30 |
| MCL | Health-based | Resolved | 2020-04-01 → 2020-06-30 |
| MCL | Health-based | Resolved | 2020-04-01 → 2020-06-30 |
| MCL | Health-based | Resolved | 2020-04-01 → 2020-06-30 |
| MCL | Health-based | Resolved | 2020-01-01 → 2020-03-31 |
| MCL | Health-based | Resolved | 2020-01-01 → 2020-03-31 |
| MCL | Health-based | Resolved | 2020-01-01 → 2020-03-31 |
| MCL | Health-based | Resolved | 2020-01-01 → 2020-03-31 |
| MCL | Health-based | Resolved | 2019-10-01 → 2019-12-31 |
| MCL | Health-based | Resolved | 2019-10-01 → 2019-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Combined Uranium | 440.4 µg/L 1468% of the EPA limit, at the 95th percentile of samples — 30 µg/L
worst single sample: 580 µg/L | 29/36 | SYR4 | 2014–2019 |
| Copper | 373.25 µg/L 29% of the EPA limit 1300 µg/L
worst single sample: 831 µg/L | 26/26 | SYR4 | 2015–2019 |
| Gross Alpha, Excl. Radon And U | 96.6 pCi/L 644% of the EPA limit, at the 95th percentile of samples — 15 pCi/L
worst single sample: 170 pCi/L | 25/36 | SYR4 | 2014–2019 |
| Nitrate | 3523.7 µg/L 35% of the EPA limit 10000 µg/L
worst single sample: 3524 µg/L | 22/22 | SYR4 | 2014–2019 |
| Combined Radium (-226 And -228) | 7.32 pCi/L 146% of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 7.5 pCi/L | 19/28 | SYR4 | 2014–2019 |
| Lead | 42.94 µg/L 286% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 55.7 µg/L | 9/23 | SYR4 | 2015–2019 |
| Chloroform | 3.86 µg/L No EPA limit set
worst single sample: 4.4 µg/L | 4/11 | SYR4 | 2014–2019 |
| TTHM | 4.775 µg/L 6% of the EPA limit 80 µg/L
worst single sample: 5.3 µg/L | 4/11 | SYR4 | 2014–2019 |
| Barium | 13.8029 µg/L 0.7% of the EPA limit 2000 µg/L
worst single sample: 14.9032 µg/L | 3/3 | SYR4 | 2016–2019 |
| Bromodichloromethane | 0.8830 µg/L No EPA limit set
worst single sample: 0.9000 µg/L | 2/11 | SYR4 | 2014–2019 |
| Dibromochloromethane | 0.6045 µg/L No EPA limit set
worst single sample: 0.6100 µg/L | 2/11 | SYR4 | 2014–2019 |
| Fluoride | 783.8 µg/L 20% of the EPA limit 4000 µg/L
worst single sample: 800 µg/L | 2/3 | SYR4 | 2016–2019 |
| Bromoform | 0.5000 µg/L No EPA limit set | 1/11 | SYR4 | 2014–2019 |
| Chromium | 1.30553 µg/L 1.3% of the EPA limit 100 µg/L | 1/3 | SYR4 | 2016–2019 |
| Dichloroacetic Acid | 1.1 µg/L No EPA limit set | 1/2 | SYR4 | 2016–2019 |
| Lead | 0.0400 mg/L 267% above the EPA limit of 0.0150 mg/L | 1/1 | LCR | 2018 |
| Monochloroacetic Acid | 2.1 µg/L No EPA limit set | 1/2 | SYR4 | 2016–2019 |
| Total Haloacetic Acids (HAA5) | 3.2 µg/L 5.3% of the EPA limit 60 µg/L | 1/2 | SYR4 | 2016–2019 |
58 contaminants tested, none detected
Utility contact
Frequently asked questions about Rolling Acres Mhp
Is Rolling Acres Mhp tap water safe to drink?
EPA monitoring detected 18 contaminants in Rolling Acres Mhp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Rolling Acres Mhp's water?
EPA monitoring detected Combined Uranium, Copper, Gross Alpha, Excl. Radon And U, Nitrate, Combined Radium (-226 And -228), and others. The full list with the level and data source for each is above.
How many people does Rolling Acres Mhp serve?
Rolling Acres Mhp reports serving 100 people in New York, per its EPA record.
Has Rolling Acres Mhp had any water quality violations?
The EPA has 310 violations on file for Rolling Acres Mhp, of which 189 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.