Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 1995-08-01 → 1995-08-31 |
| MCL | Health-based | Archived | 1995-08-01 → 1995-08-31 |
| MCL | Health-based | Archived | 1995-08-01 → 1995-08-31 |
| MR | Monitoring | Resolved | 2024-07-01 → 2024-10-01 |
| MR | Monitoring | Resolved | 2024-07-01 → 2024-10-01 |
| MR | Monitoring | Resolved | 2024-07-01 → 2024-10-01 |
| MR | Monitoring | Resolved | 2024-07-01 → 2024-10-01 |
| MR | Monitoring | Resolved | 2010-07-01 → 2010-09-30 |
| MR | Monitoring | Resolved | 2010-07-01 → 2010-09-30 |
| Other | Monitoring | Resolved | 2009-07-01 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 3600 µg/L 36% of the EPA limit 10000 µg/L
worst single sample: 4100 µg/L | 126/140 | SYR4 | 2014–2019 |
| Arsenic | 4 µg/L 40% of the EPA limit 10 µg/L
worst single sample: 6.5 µg/L | 80/95 | SYR4 | 2014–2019 |
| Copper | 721 µg/L 55% of the EPA limit 1300 µg/L
worst single sample: 1300 µg/L | 80/86 | SYR4 | 2014–2019 |
| Barium | 35.8 µg/L 1.8% of the EPA limit 2000 µg/L
worst single sample: 41 µg/L | 25/25 | SYR4 | 2014–2019 |
| Chloroform | 2.695 µg/L No EPA limit set
worst single sample: 4.5 µg/L | 22/84 | SYR4 | 2014–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 17/17 | LCR | 2024 |
| Bromodichloromethane | 6.475 µg/L No EPA limit set
worst single sample: 9.7 µg/L | 16/84 | SYR4 | 2014–2019 |
| Dibromochloromethane | 10.15 µg/L No EPA limit set
worst single sample: 13 µg/L | 16/84 | SYR4 | 2014–2019 |
| Bromoform | 4.83 µg/L No EPA limit set
worst single sample: 4.9 µg/L | 15/84 | SYR4 | 2014–2019 |
| TTHM | 25.6 µg/L 32% of the EPA limit 80 µg/L
worst single sample: 32.1 µg/L | 14/14 | SYR4 | 2014–2019 |
| Dibromoacetic Acid | 3.48 µg/L No EPA limit set
worst single sample: 3.6 µg/L | 13/14 | SYR4 | 2014–2019 |
| Lead | 190 µg/L 1267% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 460 µg/L | 13/61 | SYR4 | 2014–2017 |
| Total Haloacetic Acids (HAA5) | 4.74 µg/L 7.9% of the EPA limit 60 µg/L
worst single sample: 4.8 µg/L | 13/14 | SYR4 | 2014–2019 |
| Combined Radium (-226 And -228) | 1.75 pCi/L 35% of the EPA limit 5 pCi/L
worst single sample: 2.1 pCi/L | 11/11 | SYR4 | 2014–2019 |
| Combined Uranium | 2.16 µg/L 7.2% of the EPA limit 30 µg/L
worst single sample: 2.2 µg/L | 9/12 | SYR4 | 2014–2019 |
| Gross Alpha, Excl. Radon And U | 2.18 pCi/L 15% of the EPA limit 15 pCi/L
worst single sample: 2.9 pCi/L | 7/10 | SYR4 | 2014–2019 |
| Fluoride | 185 µg/L 4.6% of the EPA limit 4000 µg/L
worst single sample: 190 µg/L | 3/25 | SYR4 | 2014–2019 |
| Dichloroacetic Acid | 1.585 µg/L No EPA limit set
worst single sample: 1.6 µg/L | 2/14 | SYR4 | 2014–2019 |
| Lithium | 24.9 µg/L No EPA limit set | 2/8 | UCMR-5 | 2024 |
| Selenium | 1.1 µg/L 2.2% of the EPA limit 50 µg/L | 1/25 | SYR4 | 2014–2019 |
82 contaminants tested, none detected
Utility contact
Frequently asked questions about Aquarion Water/Nh
Is Aquarion Water/Nh tap water safe to drink?
EPA monitoring detected 25 contaminants in Aquarion Water/Nh's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Aquarion Water/Nh's water?
EPA monitoring detected Nitrate, Arsenic, Copper, Barium, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Aquarion Water/Nh serve?
Aquarion Water/Nh reports serving 34,000 people in Connecticut, per its EPA record.
Has Aquarion Water/Nh had any water quality violations?
The EPA has 19 violations on file for Aquarion Water/Nh, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.