← New Hampshire

Tap water quality report

Farmington Water Dept

EPA monitoring tested this supplier for 77 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

77
contaminants tested
18
detected
3,250
people served
42
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Strafford

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

42
health-based violations
56
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2006-07-01 → 2006-07-31
MCL Health-based Resolved 2006-07-01 → 2006-07-31
MCL Health-based Resolved 2006-07-01 → 2006-07-31
MCL Health-based Resolved 2006-07-01 → 2006-07-31
MCL Health-based Resolved 2005-09-01 → 2005-09-30
MCL Health-based Resolved 2005-09-01 → 2005-09-30
MCL Health-based Resolved 2005-09-01 → 2005-09-30
MCL Health-based Resolved 2005-09-01 → 2005-09-30
MCL Health-based Resolved 2005-05-01 → 2005-05-31
MCL Health-based Resolved 2005-05-01 → 2005-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
739.225 µg/L 57%
of the EPA limit 1300 µg/L
worst single sample: 768.7 µg/L
24/24 SYR4 2014–2019
Nitrate
220 µg/L 2.2%
of the EPA limit 10000 µg/L
18/24 SYR4 2014–2019
Lead
5.25 µg/L 35%
of the EPA limit 15 µg/L
worst single sample: 6.3 µg/L
16/20 SYR4 2014–2017
Bromodichloromethane
3.7 µg/L
No EPA limit set
worst single sample: 4.3 µg/L
11/20 SYR4 2014–2019
TTHM
23 µg/L 29%
of the EPA limit 80 µg/L
worst single sample: 26 µg/L
11/12 SYR4 2014–2019
Chloroform
19.5 µg/L
No EPA limit set
worst single sample: 24 µg/L
10/20 SYR4 2014–2019
Dibromochloromethane
2.5 µg/L
No EPA limit set
10/20 SYR4 2014–2019
Dichloroacetic Acid
2.52 µg/L
No EPA limit set
worst single sample: 2.6 µg/L
9/12 SYR4 2014–2019
Nitrate-Nitrite
208 µg/L 2.1%
of the EPA limit 10000 µg/L
worst single sample: 220 µg/L
9/10 SYR4 2015–2019
Total Haloacetic Acids (HAA5)
6.06 µg/L 10%
of the EPA limit 60 µg/L
worst single sample: 6.7 µg/L
9/12 SYR4 2014–2019
Bromoform
1.16 µg/L
No EPA limit set
worst single sample: 1.3 µg/L
5/20 SYR4 2014–2019
Trichloroacetic Acid
4.88 µg/L
No EPA limit set
worst single sample: 5.5 µg/L
5/12 SYR4 2014–2019
Barium
7.075 µg/L 0.4%
of the EPA limit 2000 µg/L
worst single sample: 7.1 µg/L
2/4 SYR4 2016–2019
Combined Radium (-226 And -228)
0.7700 pCi/L 15%
of the EPA limit 5 pCi/L
worst single sample: 0.8000 pCi/L
2/2 SYR4 2014
Combined Uranium
0.3850 µg/L 1.3%
of the EPA limit 30 µg/L
worst single sample: 0.4000 µg/L
2/2 SYR4 2014
Dibromoacetic Acid
1.2 µg/L
No EPA limit set
1/12 SYR4 2014–2019
Gross Alpha, Excl. Radon And U
0.8000 pCi/L 5.3%
of the EPA limit 15 pCi/L
1/2 SYR4 2014
Lead
0.0200 mg/L 133%
above the EPA limit of 0.0150 mg/L
1/1 LCR 2000
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
KEN DICKIE

Frequently asked questions about Farmington Water Dept

Is Farmington Water Dept tap water safe to drink?

EPA monitoring detected 18 contaminants in Farmington Water Dept's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Farmington Water Dept's water?

EPA monitoring detected Copper, Nitrate, Lead, Bromodichloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Farmington Water Dept serve?

Farmington Water Dept reports serving 3,250 people in New Hampshire, per its EPA record.

Has Farmington Water Dept had any water quality violations?

The EPA has 56 violations on file for Farmington Water Dept, of which 42 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.