Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2015-09-01 → 2015-09-30 |
| MCL | Health-based | Resolved | 2015-09-01 → 2015-09-30 |
| MCL | Health-based | Resolved | 2015-09-01 → 2015-09-30 |
| MCL | Health-based | Resolved | 2015-09-01 → 2015-09-30 |
| MCL | Health-based | Resolved | 2015-05-01 → 2015-05-31 |
| MCL | Health-based | Resolved | 2015-05-01 → 2015-05-31 |
| MCL | Health-based | Resolved | 2015-05-01 → 2015-05-31 |
| MCL | Health-based | Resolved | 2015-05-01 → 2015-05-31 |
| MCL | Health-based | Resolved | 2012-02-01 → 2012-02-29 |
| MCL | Health-based | Resolved | 2012-02-01 → 2012-02-29 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate-Nitrite | 6090 µg/L 61% of the EPA limit 10000 µg/L
worst single sample: 7150 µg/L | 126/126 | SYR4 | 2012–2019 |
| Fluoride | 1036 µg/L 26% of the EPA limit 4000 µg/L
worst single sample: 1090 µg/L | 105/105 | SYR4 | 2012–2019 |
| Copper | 646.5 µg/L 50% of the EPA limit 1300 µg/L
worst single sample: 1870 µg/L | 40/40 | SYR4 | 2014–2017 |
| Lead | 3.698 µg/L 25% of the EPA limit 15 µg/L
worst single sample: 4.41 µg/L | 29/40 | SYR4 | 2014–2017 |
| Combined Radium (-226 And -228) | 2.015 pCi/L 40% of the EPA limit 5 pCi/L
worst single sample: 2.3 pCi/L | 16/19 | SYR4 | 2012–2018 |
| Lithium | 19.1 µg/L No EPA limit set | 14/14 | UCMR-5 | 2024 |
| Barium | 143.75 µg/L 7.2% of the EPA limit 2000 µg/L
worst single sample: 146 µg/L | 10/10 | SYR4 | 2012–2019 |
| Lead | 0.0013 mg/L 8.7% of the EPA limit 0.0150 mg/L | 10/10 | LCR | 2023 |
| Chromium | 11.12 µg/L 11% of the EPA limit 100 µg/L
worst single sample: 11.6 µg/L | 9/10 | SYR4 | 2012–2019 |
| Selenium | 9.4625 µg/L 19% of the EPA limit 50 µg/L
worst single sample: 9.96 µg/L | 6/10 | SYR4 | 2012–2019 |
| Lasso | 0.2416 µg/L 12% of the EPA limit 2 µg/L
worst single sample: 0.2560 µg/L | 5/27 | SYR4 | 2012–2019 |
| Arsenic | 2.576 µg/L 26% of the EPA limit 10 µg/L
worst single sample: 2.63 µg/L | 4/14 | SYR4 | 2013–2019 |
| Bromoform | 1.0619 µg/L No EPA limit set
worst single sample: 1.1 µg/L | 4/23 | SYR4 | 2012–2019 |
| TTHM | 1.7375 µg/L 2.2% of the EPA limit 80 µg/L
worst single sample: 1.79 µg/L | 4/23 | SYR4 | 2012–2019 |
| Dibromochloromethane | 0.6916 µg/L No EPA limit set
worst single sample: 0.6940 µg/L | 3/23 | SYR4 | 2012–2019 |
| Atrazine | 0.0906 µg/L 3% of the EPA limit 3 µg/L
worst single sample: 0.0910 µg/L | 2/27 | SYR4 | 2012–2019 |
| Cyanide | 3.2 µg/L 1.6% of the EPA limit 200 µg/L | 1/12 | SYR4 | 2012–2019 |
| Dinoseb | 4.4 µg/L 63% of the EPA limit 7 µg/L | 1/17 | SYR4 | 2012–2019 |
86 contaminants tested, none detected
Utility contact
Frequently asked questions about Gretna, City of
Is Gretna, City of tap water safe to drink?
EPA monitoring detected 18 contaminants in Gretna, City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Gretna, City of's water?
EPA monitoring detected Nitrate-Nitrite, Fluoride, Copper, Lead, Combined Radium (-226 And -228), and others. The full list with the level and data source for each is above.
How many people does Gretna, City of serve?
Gretna, City of reports serving 8,661 people in Nebraska, per its EPA record.
Has Gretna, City of had any water quality violations?
The EPA has 51 violations on file for Gretna, City of, of which 46 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.