Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2016-10-01 → 2016-12-31 |
| MCL | Health-based | Resolved | 2016-10-01 → 2016-12-31 |
| MCL | Health-based | Resolved | 2016-10-01 → 2016-12-31 |
| MCL | Health-based | Resolved | 2016-10-01 → 2016-12-31 |
| MCL | Health-based | Resolved | 2010-04-01 → 2010-06-30 |
| MCL | Health-based | Resolved | 2010-04-01 → 2010-06-30 |
| MCL | Health-based | Resolved | 2009-07-01 → 2009-09-30 |
| MCL | Health-based | Resolved | 2009-07-01 → 2009-09-30 |
| MCL | Health-based | Resolved | 2008-10-01 → 2008-12-31 |
| MCL | Health-based | Resolved | 2008-10-01 → 2008-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate-Nitrite | 29900 µg/L 299% of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 34300 µg/L | 48/48 | SYR4 | 2012–2019 |
| Copper | 18.09 µg/L 1.4% of the EPA limit 1300 µg/L
worst single sample: 22.5 µg/L | 10/15 | SYR4 | 2012–2018 |
| Lead | 0.0011 mg/L 7.7% of the EPA limit 0.0150 mg/L | 9/9 | LCR | 2027 |
| Barium | 186.4 µg/L 9.3% of the EPA limit 2000 µg/L
worst single sample: 187 µg/L | 3/3 | SYR4 | 2012–2018 |
| Lead | 8.503 µg/L 57% of the EPA limit 15 µg/L
worst single sample: 9.31 µg/L | 3/15 | SYR4 | 2012–2018 |
| Cyanide | 5.095 µg/L 2.5% of the EPA limit 200 µg/L
worst single sample: 5.1 µg/L | 2/3 | SYR4 | 2014–2017 |
| Chromium | 4.047 µg/L 4% of the EPA limit 100 µg/L
worst single sample: 4.05 µg/L | 2/3 | SYR4 | 2012–2018 |
| Fluoride | 216.75 µg/L 5.4% of the EPA limit 4000 µg/L
worst single sample: 217 µg/L | 2/3 | SYR4 | 2012–2018 |
| Arsenic | 2.39 µg/L 24% of the EPA limit 10 µg/L | 1/1 | SYR4 | 2017 |
59 contaminants tested, none detected
Utility contact
Frequently asked questions about East Park Estates
Is East Park Estates tap water safe to drink?
EPA monitoring detected 9 contaminants in East Park Estates's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in East Park Estates's water?
EPA monitoring detected Nitrate-Nitrite, Copper, Lead, Barium, Lead, and others. The full list with the level and data source for each is above.
How many people does East Park Estates serve?
East Park Estates reports serving 100 people in Nebraska, per its EPA record.
Has East Park Estates had any water quality violations?
The EPA has 46 violations on file for East Park Estates, of which 24 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.