← Nebraska

Tap water quality report

Cedar Rapids, Village of

EPA monitoring tested this supplier for 68 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

68
contaminants tested
10
detected
382
people served
8
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Boone

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
8
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2010-06-01 → 2010-06-30
MCL Health-based Resolved 2010-06-01 → 2010-06-30
MCL Health-based Resolved 2010-06-01 → 2010-06-30
MCL Health-based Resolved 2010-06-01 → 2010-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate-Nitrite
3561.5 µg/L 36%
of the EPA limit 10000 µg/L
worst single sample: 3710 µg/L
32/32 SYR4 2012–2019
Copper
374.2 µg/L 29%
of the EPA limit 1300 µg/L
worst single sample: 426 µg/L
15/15 SYR4 2012–2018
Lead
4.118 µg/L 27%
of the EPA limit 15 µg/L
worst single sample: 5.13 µg/L
12/15 SYR4 2012–2018
Lead
0.0046 mg/L 30%
of the EPA limit 0.0150 mg/L
9/9 LCR 2024
Arsenic
2.609 µg/L 26%
of the EPA limit 10 µg/L
worst single sample: 2.61 µg/L
2/2 SYR4 2017
Barium
221.75 µg/L 11%
of the EPA limit 2000 µg/L
worst single sample: 227 µg/L
2/2 SYR4 2016
Chromium
5.9475 µg/L 5.9%
of the EPA limit 100 µg/L
worst single sample: 6.01 µg/L
2/2 SYR4 2016
Selenium
5.287 µg/L 11%
of the EPA limit 50 µg/L
worst single sample: 5.29 µg/L
2/2 SYR4 2016
Combined Radium (-226 And -228)
2.87 pCi/L 57%
of the EPA limit 5 pCi/L
1/2 SYR4 2014–2017
Fluoride
237 µg/L 5.9%
of the EPA limit 4000 µg/L
1/2 SYR4 2016
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ROBINSON, RITA M
Phone
308-358-0240
Email
[email protected]

Frequently asked questions about Cedar Rapids, Village of

Is Cedar Rapids, Village of tap water safe to drink?

EPA monitoring detected 10 contaminants in Cedar Rapids, Village of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Cedar Rapids, Village of's water?

EPA monitoring detected Nitrate-Nitrite, Copper, Lead, Lead, Arsenic, and others. The full list with the level and data source for each is above.

How many people does Cedar Rapids, Village of serve?

Cedar Rapids, Village of reports serving 382 people in Nebraska, per its EPA record.

Has Cedar Rapids, Village of had any water quality violations?

The EPA has 8 violations on file for Cedar Rapids, Village of, of which 8 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.