← North Dakota

Tap water quality report

South Central Rwd-Emmons

EPA monitoring tested this supplier for 108 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
21
detected
3,650
people served
0
health-based violations
Water source
Surface water
Ownership
Private
Counties served
Emmons

Compliance record

No violations on file. The EPA has no formal drinking-water violations recorded for this supplier.

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
472.9 µg/L 36%
of the EPA limit 1300 µg/L
worst single sample: 564 µg/L
47/50 SYR4 2012–2019
Bromodichloromethane
8.406 µg/L
No EPA limit set
worst single sample: 10.18 µg/L
37/37 SYR4 2013–2019
Chloroform
65.068 µg/L
No EPA limit set
worst single sample: 79.81 µg/L
37/37 SYR4 2013–2019
Dibromochloromethane
2.904 µg/L
No EPA limit set
worst single sample: 3.45 µg/L
37/37 SYR4 2013–2019
TTHM
77.134 µg/L 96%
of the EPA limit 80 µg/L
worst single sample: 93.11 µg/L
37/37 SYR4 2013–2019
Dichloroacetic Acid
18.44 µg/L
No EPA limit set
worst single sample: 26.3 µg/L
35/35 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
30.876 µg/L 51%
of the EPA limit 60 µg/L
worst single sample: 47.16 µg/L
35/35 SYR4 2013–2019
Trichloroacetic Acid
10.9755 µg/L
No EPA limit set
worst single sample: 16.3 µg/L
34/35 SYR4 2013–2019
Bromate
7.535 µg/L 75%
of the EPA limit 10 µg/L
worst single sample: 8.3 µg/L
18/30 SYR4 2013–2019
Lead
3.188 µg/L 21%
of the EPA limit 15 µg/L
worst single sample: 3.86 µg/L
17/50 SYR4 2012–2019
Monochloroacetic Acid
5.942 µg/L
No EPA limit set
worst single sample: 6.58 µg/L
12/35 SYR4 2013–2019
Nitrate-Nitrite
70 µg/L 0.7%
of the EPA limit 10000 µg/L
10/18 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
6/6 LCR 2025
Barium
34.04 µg/L 1.7%
of the EPA limit 2000 µg/L
worst single sample: 34.6 µg/L
5/5 SYR4 2012–2018
Fluoride
986 µg/L 25%
of the EPA limit 4000 µg/L
worst single sample: 1000 µg/L
5/5 SYR4 2012–2018
Combined Radium (-226 And -228)
0.7397 pCi/L 15%
of the EPA limit 5 pCi/L
worst single sample: 0.7679 pCi/L
4/4 SYR4 2012–2018
Lithium
24.9 µg/L
No EPA limit set
4/4 UCMR-5 2025
Gross Alpha, Excl. Radon And U
2.321 pCi/L 15%
of the EPA limit 15 pCi/L
worst single sample: 2.5 pCi/L
3/4 SYR4 2012–2018
Combined Uranium
0.8379 µg/L 2.8%
of the EPA limit 30 µg/L
worst single sample: 0.8800 µg/L
2/4 SYR4 2012–2018
Arsenic
2.66 µg/L 27%
of the EPA limit 10 µg/L
1/6 SYR4 2012–2016
Chromium
8.9 µg/L 8.9%
of the EPA limit 100 µg/L
1/5 SYR4 2012–2018
87 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
KIRSCHMANN, LARRY
Phone
701-258-8710
Email
[email protected]

Frequently asked questions about South Central Rwd-Emmons

Is South Central Rwd-Emmons tap water safe to drink?

EPA monitoring detected 21 contaminants in South Central Rwd-Emmons's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in South Central Rwd-Emmons's water?

EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does South Central Rwd-Emmons serve?

South Central Rwd-Emmons reports serving 3,650 people in North Dakota, per its EPA record.

Has South Central Rwd-Emmons had any water quality violations?

The EPA has no formal drinking-water violations on file for South Central Rwd-Emmons.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.